English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Decomposition of time-dependent fluorescence signals reveals codon-specific kinetics of protein synthesis

MPS-Authors
/persons/resource/persons225322

Haase,  Nadin
Sophia Rudorf, Theorie & Bio-Systeme, Max Planck Institute of Colloids and Interfaces, Max Planck Society;

/persons/resource/persons121584

Lipowsky,  Reinhard
Reinhard Lipowsky, Theorie & Bio-Systeme, Max Planck Institute of Colloids and Interfaces, Max Planck Society;

/persons/resource/persons121790

Rudorf,  Sophia
Reinhard Lipowsky, Theorie & Bio-Systeme, Max Planck Institute of Colloids and Interfaces, Max Planck Society;
Sophia Rudorf, Theorie & Bio-Systeme, Max Planck Institute of Colloids and Interfaces, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

Article.pdf
(Publisher version), 2MB

Supplementary Material (public)
There is no public supplementary material available
Citation

Haase, N., Holtkamp, W., Lipowsky, R., Rodnina, M., & Rudorf, S. (2018). Decomposition of time-dependent fluorescence signals reveals codon-specific kinetics of protein synthesis. Nucleic Acids Research (London), gky740. doi:10.1093/nar/gky740.


Cite as: https://hdl.handle.net/21.11116/0000-0001-EDB5-8
Abstract
During protein synthesis, the nascent peptide chain traverses the peptide exit tunnel of the ribosome. We monitor the co-translational movement of the nascent peptide using a fluorescent probe attached to the N-terminus of the nascent chain. Due to fluorophore quenching, the time-dependent fluorescence signal emitted by an individual peptide is determined by co-translational events, such as secondary structure formation and peptide-tunnel interactions. To obtain information on these individual events, the measured ensemble fluorescence signal has to be decomposed into position-dependent intensities. Here, we describe mRNA translation as a Markov process with specific fluorescence intensities assigned to the different states of the process. Combining the computed stochastic time evolution of the translation process with a sequence of observed ensemble fluorescence time courses, we compute the unknown position-specific intensities and obtain detailed information on the kinetics of the translation process. In particular, we find that translation of poly(U) mRNAs dramatically slows down at the fourth UUU codon. The method presented here detects subtle differences in the position-specific fluorescence intensities and thus provides a novel approach to study translation kinetics in ensemble experiments.