English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Microscopic oxygen imaging based on fluorescein bleaching efficiency measurements

MPS-Authors
/persons/resource/persons210267

Beutler,  M.
Permanent Research Group Microsensor, Max Planck Institute for Marine Microbiology, Max Planck Society;

/persons/resource/persons210447

Heisterkamp,  I.
Permanent Research Group Microsensor, Max Planck Institute for Marine Microbiology, Max Planck Society;

/persons/resource/persons210678

Piltz,  B.
IMPRS MarMic, Max Planck Institute for Marine Microbiology, Max Planck Society;

/persons/resource/persons56955

Stief,  P.
Permanent Research Group Microsensor, Max Planck Institute for Marine Microbiology, Max Planck Society;

/persons/resource/persons210257

De Beer,  D.
Permanent Research Group Microsensor, Max Planck Institute for Marine Microbiology, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Beutler, M., Heisterkamp, I., Piltz, B., Stief, P., & De Beer, D. (2014). Microscopic oxygen imaging based on fluorescein bleaching efficiency measurements. Microscopy Research and Technique, 77(5): 1, pp. 341-347.


Cite as: https://hdl.handle.net/21.11116/0000-0001-C589-6
Abstract
Photobleaching of the fluorophore fluorescein in an aqueous solution is dependent on the oxygen concentration. Therefore, the time-dependent bleaching behavior can be used to measure of dissolved oxygen concentrations. The method can be combined with epi-fluorescence microscopy. The molecular states of the fluorophore can be expressed by a three-state energy model. This leads to a set of differential equations which describe the photobleaching behavior of fluorescein. The numerical solution of these equations shows that in a conventional wide-field fluorescence microscope, the fluorescence of fluorescein will fade out faster at low than at high oxygen concentration. Further simulation showed that a simple ratio function of different time-points during a fluorescence decay recorded during photobleaching could be used to describe oxygen concentrations in an aqueous solution. By careful choice of dye concentration and excitation light intensity the sensitivity in the oxygen concentration range of interest can be optimized. In the simulations, the estimation of oxygen concentration by the ratio function was very little affected by the pH value in the range of pH 6.5-8.5. Filming the fluorescence decay by a charge-coupled-device (ccd) camera mounted on a fluorescence microscope allowed a pixelwise estimation of the ratio function in a microscopic image. Use of a microsensor and oxygen-consuming bacteria in a sample chamber enabled the calibration of the system for quantification of absolute oxygen concentrations. The method was demonstrated on nitrifying biofilms growing on snail and mussel shells, showing clear effects of metabolic activity on oxygen concentrations. Microsc. Res. Tech. 77:341-347, 2014. (c) 2014 Wiley Periodicals, Inc.