English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Micromechanical properties of strain-sensitive lyriform organs of a wandering spider (Cupiennius salei)

MPS-Authors

Barth,  Friedrich G.
Biomaterialien, Max Planck Institute of Colloids and Interfaces, Max Planck Society;

/persons/resource/persons122098

Zlotnikov,  Igor
Peter Fratzl, Biomaterialien, Max Planck Institute of Colloids and Interfaces, Max Planck Society;

/persons/resource/persons121733

Politi,  Yael
Yael Politi, Biomaterialien, Max Planck Institute of Colloids and Interfaces, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Young, S. L., Chyasnavichyus, M., Barth, F. G., Zlotnikov, I., Politi, Y., & Tsukruk, V. V. (2016). Micromechanical properties of strain-sensitive lyriform organs of a wandering spider (Cupiennius salei). Acta Biomaterialia, 41, 40-51. doi:10.1016/j.actbio.2016.06.009.


Cite as: https://hdl.handle.net/11858/00-001M-0000-002A-E5B3-1
Abstract
Highly sensitive lyriform organs located on the legs of the wandering spider Cupiennius salei allow the spider to detect nanometer-scale strains in the exoskeleton resulting from locomotion or substrate vibrations. Morphological features of the lyriform organs result in their specialization and selective sensitivity to specific mechanical stimuli, which make them interesting for bioinspired strain sensors. Here we utilize atomic force microscopy (AFM)-based force spectroscopy to probe nano-scale mechanical properties of the covering membrane of two lyriform organs found on Cupiennius salei: the vibration sensitive metatarsal lyriform organ (HS10) and the proprioreceptive tibial lyriform organ (HS8). Force distance curves (FDCs) obtained from \AFM\} measurements displayed characteristic multi-layer structure behavior, with calculated elastic moduli ranging from 150 \{MPa\} to 500 \{MPa\ for different regions and indentation depths. In addition, we probed the lyriform organs with a large radius tip, which allowed for probing structural deformation by the application of high forces and large scale deformations without damaging the surface. The viscoelastic behavior of the sensor materials observed in this probing suggests mechanical relaxation times potentially playing a role in the time-dependent behavior of the lyriform organs.