English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Mapping molecules in scanning far-field fluorescence nanoscopy.

MPS-Authors
/persons/resource/persons79571

Ta,  H.
Department of NanoBiophotonics, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15318

Keller,  J.
Department of NanoBiophotonics, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons32717

Haltmeier,  M.
Research Group of Statistical Inverse-Problems in Biophysics, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons32719

Munk,  A.
Research Group of Statistical Inverse-Problems in Biophysics, MPI for biophysical chemistry, Max Planck Society;

/persons/resource/persons15210

Hell,  S. W.
Department of NanoBiophotonics, MPI for biophysical chemistry, Max Planck Society;

Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

2181635.pdf
(Publisher version), 882KB

Supplementary Material (public)

2181635_Suppl_1.pdf
(Supplementary material), 3MB

2181635_Suppl_2.avi
(Supplementary material), 10MB

2181635_Suppl_3.zip
(Supplementary material), 51KB

Citation

Ta, H., Keller, J., Haltmeier, M., Saka, S. K., Schmied, J., Opazo, F., et al. (2015). Mapping molecules in scanning far-field fluorescence nanoscopy. Nature Communications, 6: 7977. doi:10.1038/ncomms8977.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0028-374B-2
Abstract
In fluorescence microscopy, the distribution of the emitting molecule number in space is usually obtained by dividing the measured fluorescence by that of a single emitter. However, the brightness of individual emitters may vary strongly in the sample or be inaccessible. Moreover, with increasing (super-) resolution, fewer molecules are found per pixel, making this approach unreliable. Here we map the distribution of molecules by exploiting the fact that a single molecule emits only a single photon at a time. Thus, by analysing the simultaneous arrival of multiple photons during confocal imaging, we can establish the number and local brightness of typically up to 20 molecules per confocal (diffraction sized) recording volume. Subsequent recording by stimulated emission depletion microscopy provides the distribution of the number of molecules with subdiffraction resolution. The method is applied to mapping the three-dimensional nanoscale organization of internalized transferrin receptors on human HEK293 cells.