Analysing uncertainties in the calculation of fluxes using whole-plant chambers: random and systematic errors

MPG-Autoren
Es sind keine MPG-Autoren in der Publikation vorhanden
Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Pérez-Priego, O., López-Ballesteros, A., Sánchez-Cañete, E. P., Serrano-Ortiz, P., Kutzbach, L., Domingo, F., et al. (2015). Analysing uncertainties in the calculation of fluxes using whole-plant chambers: random and systematic errors. Plant and Soil, 393(1), 229-244. doi:10.1007/s11104-015-2481-x.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0027-A880-A
Zusammenfassung
Aims Gas exchange measurements on individual plants depend largely on chamber systems, and uncertainties and corrections in current flux calculation procedures require further assessment. Methods We present a practical study with novel methods for analyses of flux uncertainties in an original chamber design excluding soil fluxes and allowing simultaneous measurements of whole-plant photosynthesis and transpiration. Results Results indicate that random errors caused by IRGA noise and the lack of criteria to optimize the time window (TW) of chamber enclosure lead to significant flux uncertainties (12 %). Although enclosure should be rapid to minimize plant disturbances, longer TWs (3 min) increase confidence in flux estimates. Indeterminate stabilization periods in existing calculation protocols cause significant systematic errors. Stabilization times were identified via the change-point detection method, and flux uncertainties were reduced. Photosynthesis was overestimated by up to 28 % when not correcting the evolving CO2 molar fraction for water vapour dilution. Leakage can compromise flux estimates, but was negligible (ca. 2 %) here due to the large chamber-headspace and relatively small values of both collar contact length and closure time. Conclusions A bootstrapping, resampling-based flux calculation method is presented and recommended to better assess random errors and improve flux precision. We present practical recommendations for the use of whole-plant chambers.