Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Dual-Frequency Calcium-Responsive MRI Agents

MPG-Autoren
/persons/resource/persons83998

Kadjane,  P
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Hagberg,  G
Max Planck Institute for Biological Cybernetics, Max Planck Society;
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84063

Logothetis,  NK
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83784

Angelovski,  G
Research Group MR Neuroimaging Agents, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Kadjane, P., Platas-Iglesias, C., Boehm-Sturm, P., Truffault, V., Hagberg, G., Hoehn, M., et al. (2014). Dual-Frequency Calcium-Responsive MRI Agents. Chemistry: A European Journal, 20(24), 7351-7362. doi:10.1002/chem.201400159.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0027-800D-3
Zusammenfassung
Responsive or smart magnetic resonance imaging (MRI) contrast agents are molecular sensors that alter the MRI signal upon changes in a particular parameter in their microenvironment. Consequently, they could be exploited for visualization of various biochemical events that take place at molecular and cellular levels. In this study, a set of dual-frequency calcium-responsive MRI agents are reported. These are paramagnetic, fluorine-containing complexes that produce remarkably high MRI signal changes at the 1H and 19F frequencies at varying Ca2+ concentrations. The nature of the processes triggered by Ca2+ was revealed, allowing a better understanding of these complex systems and their further improvement. The findings indicate that these double-frequency tracers hold great promise for development of novel functional MRI methods.