Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Ion-chromatographic determination of low concentrations of nitrate in solutions of high salinity

MPG-Autoren
/persons/resource/persons62521

Raessler,  M.
Service Facility Spectrometry, Dr. M. Raessler, Max Planck Institute for Biogeochemistry, Max Planck Society;

/persons/resource/persons62411

Hilke,  I.
Service Facility Routine Measurements and Analysis (RoMA), I. Hilke, Max Planck Institute for Biogeochemistry, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Raessler, M., & Hilke, I. (2006). Ion-chromatographic determination of low concentrations of nitrate in solutions of high salinity. Microchimica Acta, 154(1-2), 27-29.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-000E-D46E-8
Zusammenfassung
The determination of low concentrations of inorganic anions in water samples of high salinity is one of the most difficult tasks in analytical chemistry. There is, however, an increasing demand for the exact and reliable determination of nutrients even at very low concentration levels in environmental samples of complex composition. We therefore present the development, quality control and application of an easy and rugged method that makes possible the determination of trace amounts of nitrate in solutions with high concentrations of chloride (> 30 000 mu gL(-1)) and a hundred-fold excess of bromide ions, based on ion chromatography with UV detection at lambda = 210 nm. While chloride ions show no absorbance at this wavelength, a bromide concentration > 1500 mu gL(-1) severely interferes with nitrate determination at the trace level. On the contrary, at nitrate concentrations of > 500 mu gL(-1), this bromide interference becomes negligible. Consequently, to overcome the impact of bromide on the trace level determination of nitrate, all samples are spiked with a definite volume of a nitrate standard solution to obtain an overall nitrate concentration of > 500 mu gL(-1) which allows the exact and reliable determination of nitrate concentrations down to 25 mu gL(-1). We will report the successful application of the method to samples of high salinity. [References: 6]