de.mpg.escidoc.pubman.appbase.FacesBean
Deutsch
 
Hilfe Wegweiser Impressum Kontakt Einloggen
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Precision Muon Reconstruction in Double Chooz

MPG-Autoren
http://pubman.mpdl.mpg.de/cone/persons/resource/persons30347

Buck,  C.
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

http://pubman.mpdl.mpg.de/cone/persons/resource/persons30570

Haser,  Julia
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

http://pubman.mpdl.mpg.de/cone/persons/resource/persons30647

Kaether,  F.
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

http://pubman.mpdl.mpg.de/cone/persons/resource/persons30768

Lindner,  M.
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

http://pubman.mpdl.mpg.de/cone/persons/resource/persons37603

Reinhold,  Bernd
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

http://pubman.mpdl.mpg.de/cone/persons/resource/persons31154

Wagner,  Stefan
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

http://pubman.mpdl.mpg.de/cone/persons/resource/persons37605

Watanabe,  H.
Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society;

Volltexte (frei zugänglich)

1405.6227.pdf
(Preprint), 672KB

Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Double Chooz Collaboration, Abe, Y., Anjos, J. C. d., Barriere, J. C., Baussan, E., Bekman, I., et al. (2014). Precision Muon Reconstruction in Double Chooz. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 764, 330-339. doi:10.1016/j.nima.2014.07.058.


Zitierlink: http://hdl.handle.net/11858/00-001M-0000-0025-04B4-0
Zusammenfassung
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a through-going muon intersecting the center of the detector, the resolution is ~40 mm in each transverse dimension. High quality muon reconstruction is an important tool for reducing the impact of the cosmogenic isotope background in Double Chooz.