Comparison of static chambers to measure CH4 emissions from soils

MPG-Autoren
Es sind keine MPG-Autoren in der Publikation vorhanden
Externe Ressourcen
Es sind keine Externen Ressourcen verfügbar
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Pihlatie, M. K., Christiansen, J. R., Aaltonen, H., Korhonen, J. F. J., Nordbo, A., Rasilo, T., et al. (2013). Comparison of static chambers to measure CH4 emissions from soils. AGRICULTURAL AND FOREST METEOROLOGY, 171, 124-136. doi:10.1016/j.agrformet.2012.11.008.


Zitierlink: http://hdl.handle.net/11858/00-001M-0000-0019-D91F-E
Zusammenfassung
The static chamber method (non-flow-through-non-steady-state chambers) is the most common method to measure fluxes of methane (CH4) from soils. Laboratory comparisons to quantify errors resulting from chamber design, operation and flux calculation methods are rare. We tested fifteen chambers against four flux levels (FL) ranging from 200 to 2300 mu g CH4 M-2 II-1. The measurements were conducted on a calibration tank using three quartz sand types with soil porosities of 53% (dry fine sand, S1), 47% (dry coarse sand, S2), and 33% (wetted fine sand, S3). The chambers tested ranged from 0.06 to 1.8 m in height, and 0.02 to 0.195 m(3) in volume, 7 of them were equipped with a fan, and 1 with a vent-tube. We applied linear and exponential flux calculation methods to the chamber data and compared these chamber fluxes to the reference fluxes from the calibration tank. The chambers underestimated the reference fluxes by on average 33% by the linear flux calculation method (R-Iin), whereas the chamber fluxes calculated by the exponential flux calculation method (R-exp) did not significantly differ from the reference fluxes (p <0.05). The flux under- or overestimations were chamber specific and independent of flux level. Increasing chamber height, area and volume significantly reduced the flux underestimation (p <0.05). Also, the use of non-linear flux calculation method significantly improved the flux estimation; however, simultaneously the uncertainty in the fluxes was increased. We provide correction factors, which can be used to correct the under- or overestimation of the fluxes by the chambers in the experiment. (C) 2012 Elsevier B.V. All rights reserved.