Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Poster

Functional MR imaging of the awake monkey in a novel vertical large-bore 7 Tesla setup

MPG-Autoren
/persons/resource/persons84137

Pfeuffer,  J
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84130

Pauls,  J
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83787

Augath,  MA
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84237

Steudel,  T
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84063

Logothetis,  NK
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Externe Ressourcen
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)

pdf2038.pdf
(beliebiger Volltext), 30KB

Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Pfeuffer, J., Pauls, J., Augath, M., Steudel, T., Merkle, H., & Logothetis, N. (2003). Functional MR imaging of the awake monkey in a novel vertical large-bore 7 Tesla setup. Poster presented at 11th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM 2003), Toronto, Canada.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0013-DC2F-B
Zusammenfassung
First fMRI results in the awake trained monkey (Macaca mulatta) using a novel vertical 7T/60cm MR system are reported. The setup was custom-designed for MR imaging of monkeys in upright position and simultaneous electrophysiological recording. Using fast gradients and optimized RF coils, the benefits of high magnetic field with increased signal and contrast-to-noise ratio are demonstrated in high-resolution anatomical and functional images.