日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細


公開

会議論文

Enhancement of Kinesthetic Perception for Microsurgical Teleoperation using Impedance-Shaping

MPS-Authors
There are no MPG-Authors in the publication available
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
フルテキスト (公開)
公開されているフルテキストはありません
付随資料 (公開)
There is no public supplementary material available
引用

Son, H., & Lee, D. (2008). Enhancement of Kinesthetic Perception for Microsurgical Teleoperation using Impedance-Shaping. In 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (pp. 1939-1942). Piscataway, NJ, USA: IEEE.


引用: https://hdl.handle.net/11858/00-001M-0000-0013-C7A5-A
要旨
A new control scheme is developed in this paper for a bilateral teleoperation system for microsurgical applications. The main objective of the proposed control scheme is to enhance the kinesthetic perception of the operator. First, the kinesthetic perception, based on psychophysics, is classified into three metrics of detection, sensitivity of detection, and discrimination. Additionally, a new performance index is introduced as a combination of these three metrics to quantify the kinesthetic performance. Second, modified macro-micro bilateral control system using an impedance-shaping method is proposed. The proposed controller can increase kinesthetic perception by shaping and magnifying the transmitted impedance to the operator. Finally, the performance of the proposed controller is verified in a comparison with the two-channel position-position (PP) controller, the two-channel force-position (FP) controller, and the four-channel transparency- optimized controller.