Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

23Na MR Imaging at 7 T after Knee Matrix–associated Autologous Chondrocyte Transplantation Preliminary Results

MPG-Autoren
Es sind keine MPG-Autoren in der Publikation vorhanden
Externe Ressourcen
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Trattnig, S., Welsch, G., Juras, V., Szomolanyi, P., Mayerhoefer, M., Stelzeneder, D., et al. (2010). 23Na MR Imaging at 7 T after Knee Matrix–associated Autologous Chondrocyte Transplantation Preliminary Results. Radiology, 257(1), 175-184. doi:10.1148/radiol.10100279.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0013-BDAA-D
Zusammenfassung
Purpose: To evaluate the feasibility of sodium 7-T magnetic resonance (MR) imaging in repaired tissue and native cartilage of patients after matrix-associated autologous chondrocyte transplantation (MACT) and compare results with delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC) at 3 T.
Materials and Methods: Ethical approval was provided by the local ethics committee; written informed consent was obtained from all patients. Six women and six men (mean age, 32.8 year ± 8.2 [standard deviation] and 32.3 years ± 12.7, respectively) were included. Mean time between MACT and MR was 56 months ± 28. A variable three-dimensional (3D) gradient-echo (GRE) dual–flip-angle technique was used for T1 mapping before and after contrast agent administration at 3 T. All patients were also examined at 7 T (mean delay, 70.5 days ± 80.1). A sodium 23–only transmit-receive knee coil was used with the 3D GRE sequence. A statistical analysis of variance and Pearson correlation were applied.
Results: Mean signal-to-noise ratio (SNR) was 24 in native cartilage and was 16 in transplants (P < .001). Mean sodium signal intensities normalized with the reference sample were 174 ± 53 and 267 ± 42 for repaired tissue in the cartilage transplant and healthy cartilage, respectively (P < .001). Mean postcontrast T1 values were 510 msec ± 195 and 756 msec ± 188 for repaired tissue and healthy cartilage, respectively (P = .005). Mean score of MR observation of cartilage repair tissue was 75 ± 14. Association between postcontrast T1 and normalized sodium signal values showed a high Pearson correlation coefficient (R) of 0.706 (P = .001). A high correlation of R = 0.836 (P = .001) was found between ratios of normalized sodium values and ratios of T1 postcontrast values.
Conclusion: With the modified 3D GRE sequence at 7 T, a sufficiently high SNR in sodium images was achieved, allowing for differentiation of repaired tissue from native cartilage after MACT. A strong correlation was found between sodium imaging and dGEMRIC in patients after MACT.