de.mpg.escidoc.pubman.appbase.FacesBean
Deutsch
 
Hilfe Wegweiser Impressum Kontakt Einloggen
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Adiabatic operation of chromatographic fixed-bed reactors

MPG-Autoren
http://pubman.mpdl.mpg.de/cone/persons/resource/persons86529

Zhang,  L.
Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society;

http://pubman.mpdl.mpg.de/cone/persons/resource/persons86477

Seidel-Morgenstern,  A.
Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society;
Otto-von-Guericke-Universität Magdeburg, External Organizations;

Externe Ressourcen
Es sind keine Externen Ressourcen verfügbar
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Sainio, T., Zhang, L., & Seidel-Morgenstern, A. (2011). Adiabatic operation of chromatographic fixed-bed reactors. Chemical Engineering Journal, 168(2), 861-871. doi:10.1016/j.cej.2011.02.010.


Zitierlink: http://hdl.handle.net/11858/00-001M-0000-0013-8D08-F
Zusammenfassung
Adiabatic operation of single column chromatographic reactors was investigated experimentally and using numerical simulations. Esterification of acetic acid with alcohols to produce methyl acetate and ethyl acetate was carried out under isothermal and adiabatic conditions. Higher conversions of the acids, as well as higher ester/water mole ratio in the product fraction, were obtained in the adiabatic reactor than in the isothermal reactor. Improved performance was attributed to a thermal wave that travels through the reactor together with the reaction front. It was shown that thermal effects in such systems originate from reaction heat, adsorption enthalpies, as well as the enthalpy of mixing. Numerical simulations were carried out to investigate under which conditions adiabatic operation of a fixed-bed chromatographic reactor is potentially beneficial. The influence of physical properties of the reaction system (heat capacities of the liquid and solid phases, reaction rate, and separation factor) and operating parameters (injection volume of reactant and residence time) on the process performance was demonstrated. Copyright © 2011 Elsevier B.V. All rights reserved. [accessed April 15th 2011]