Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

First experimental proof for aberration correction in XPEEM: Resolution, transmission enhancement, and limitation by space charge effects

MPG-Autoren
/persons/resource/persons22076

Schmidt,  Thomas
Chemical Physics, Fritz Haber Institute, Max Planck Society;

/persons/resource/persons22039

Sala,  Alessandro
Chemical Physics, Fritz Haber Institute, Max Planck Society;

/persons/resource/persons21844

Marchetto,  Helder
Chemical Physics, Fritz Haber Institute, Max Planck Society;

/persons/resource/persons21524

Freund,  Hans-Joachim
Chemical Physics, Fritz Haber Institute, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Schmidt, T., Sala, A., Marchetto, H., Umbach, E., & Freund, H.-J. (2013). First experimental proof for aberration correction in XPEEM: Resolution, transmission enhancement, and limitation by space charge effects. Ultramicroscopy, 126, 23-32. doi:10.1016/j.ultramic.2012.11.004.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-000E-DF95-7
Zusammenfassung
The positive effect of double aberration correction in x-ray induced Photoelectron Emission Microscopy (XPEEM) has been successfully demonstrated for both, the lateral resolution and the transmission, using the Au 4f XPS peak for element specific imaging at a kinetic energy of 113 eV. The lateral resolution is improved by a factor of four, compared to a non-corrected system, whereas the transmission is enhanced by a factor of 5 at a moderate resolution of 80 nm. With an optimized system setting, a lateral resolution of 18 nm could be achieved, which is up to now the best value reported for energy filtered XPEEM imaging. However, the absolute resolution does not yet reach the theoretical limit of 2 nm, which is due to space charge limitation. This occurs along the entire optical axis up to the contrast aperture. In XPEEM the pulsed time structure of the exciting soft x-ray light source causes a short and highly intense electron pulse, which results in an image blurring. In contrast, the imaging with elastically reflected electrons in the low energy electron microscopy (LEEM) mode yields a resolution clearly below 5 nm. Technical solutions to reduce the space charge effect in an aberration-corrected spectro-microscope are discussed.