English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Novel silver-tubing method for quantitative introduction of water into high-temperature conversion systems for stable hydrogen and oxygen isotopic measurements

MPS-Authors
/persons/resource/persons62345

Brand,  Willi A.
Service Facility Stable Isotope, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society;

/persons/resource/persons62380

Geilmann,  Heike
Service Facility Stable Isotope, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Qi, H. P., Groning, M., Coplen, T. B., Buck, B., Mroczkowski, S. J., Brand, W. A., et al. (2010). Novel silver-tubing method for quantitative introduction of water into high-temperature conversion systems for stable hydrogen and oxygen isotopic measurements. Rapid Communications in Mass Spectrometry, 24(13), 1821-1827. doi:10.1002/rcm.4559.


Cite as: https://hdl.handle.net/11858/00-001M-0000-000E-DA83-A
Abstract
A new method to seal water in silver tubes for use in a TC/EA (thermal conversion/elemental analyzer) reduction unit using a semi-automated sealing apparatus can yield reproducibilities (1 standard deviation) of delta H-2 and delta O-18 measurements of 1.0 parts per thousand and 0.06 parts per thousand, respectively. These silver tubes containing reference waters may be preferred for the calibration of H- and O-bearing materials analyzed with a TC/EA reduction unit. The new sealing apparatus employs a computer-controlled stepping motor to produce silver tubes identical in length. The reproducibility of the mass of water sealed in tubes (in a range of 200-400 mu g) can be as good as 1%. Approximately 99% of the sealed silver tubes are satisfactory (leak free). Although silver tubes sealed with reference waters are robust and can be shaken or heated to 110 degrees C with no loss of integrity, they should not be frozen because the expansion during the phase transition of water to ice will break the cold seals and all the water will be lost. The tubes should be shipped in insulated containers. This new method eliminates air inclusions and isotopic fractionation of water associated with the loading of water into capsules using a syringe. The method is also more than an order of magnitude faster than preparing water samples in ordinary Ag capsules. Nevertheless, some laboratories may prefer loading water into silver capsules because expensive equipment is not needed, but users of this method are cautioned to apply the necessary corrections for evaporation, back exchange with laboratory atmospheric moisture, and blanks. Copyright (C) 2010 John Wiley & Sons, Ltd.