Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  High-resolution colocalization of single dye molecules by fluorescence lifetime imaging microscopy

Heilemann, M., Herten, D. P., Heintzmann, R., Cremer, C., Mueller, C., Tinnefeld, P., et al. (2002). High-resolution colocalization of single dye molecules by fluorescence lifetime imaging microscopy. Analytical Chemistry, 74(14), 3511-3517. Retrieved from http://pubs.acs.org/doi/pdfplus/10.1021/ac025576g.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
16508.pdf (Verlagsversion), 0B
 
Datei-Permalink:
-
Name:
16508.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Heilemann, M., Autor
Herten, D. P., Autor
Heintzmann, R.1, Autor           
Cremer, C., Autor
Mueller, C., Autor
Tinnefeld, P., Autor
Weston, K. D., Autor
Wolfrum, J., Autor
Sauer, M., Autor
Affiliations:
1Department of Molecular Biology, MPI for biophysical chemistry, Max Planck Society, ou_578628              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Conventional fluorescence microscopy can be used to determine the positions of objects in space when those objects are separated by distances greater than several hundred nanometers, as restricted by the diffraction limit of light. Fluorescence microscopy/spectroscopy based on fluorescence resonance energy- transfer techniques can be used to measure separation distances below similar to10 nm. To fill the gap between these fundamental limits, we have developed an alternative technique for high-resolution colocalization of fluorescent dyes. The technique is based on fluorescence lifetime imaging. Under favorable conditions, the method can be used to distinguish, and to measure the distance between, two dye molecules that are less than 30 nm apart. To demonstrate the method, lifetime images of a mixture of Cy5 and JF9 (rhodamine derivative) molecules statistically adsorbed on a glass surface were acquired and analyzed. Since these two molecular species differ in fluorescence lifetime (for Cy5, tau(f) = 2.0 us, and for JF9, tau(f) = 4.0 ns), it is possible to assign the contribution of fluorescence of the two dye types to each image pixel using a pattern recognition technique. Since both dye types can be excited using the same laser wavelength, the measurement is free of chromatic aberrations. The results presented demonstrate the first high-precision distance measurements between single conventional fluorescent dyes based solely on fluorescence lifetime.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2002-07-15
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: eDoc: 16508
URI: http://pubs.acs.org/doi/pdfplus/10.1021/ac025576g
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Analytical Chemistry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 74 (14) Artikelnummer: - Start- / Endseite: 3511 - 3517 Identifikator: -