Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Ultrasensitive investigations of biological systems by fluorescence correlation spectroscopy

Haustein, E., & Schwille, P. (2003). Ultrasensitive investigations of biological systems by fluorescence correlation spectroscopy. Methods, 29(2), 153-166. Retrieved from http://www.sciencedirect.com/science?_ob=MImg&_imagekey=B6WN5-47WD7N5-8-2Y&_cdi=6953&_user=38661&_pii=S1046202302003067&_orig=search&_coverDate=02%2F28%2F2003&_sk=999709997&view=c&wchp=dGLzVlz-zSkzV&md5=7ddf89f8be83c219ac7c855e4bd4b762&ie=/sdarticle.pdf.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
20757.pdf (Verlagsversion), 0B
Name:
20757.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Haustein, E., Autor
Schwille, P.1, Autor           
Affiliations:
1Research Group of Experimental Biophysics, MPI for biophysical chemistry, Max Planck Society, ou_578554              

Inhalt

einblenden:
ausblenden:
Schlagwörter: fluctuations; FCS; diffusion; membrane
 Zusammenfassung: Fluorescence correlation spectroscopy (FCS) extracts information about molecular dynamics from the tiny fluctuations that can be observed in the emission of small ensembles of fluorescent molecules in thermodynamic equilibrium. Employing a confocal setup in conjunction with highly dilute samples, the average number of fluorescent particles simultaneously within the measurement volume (similar to1 fl) is minimized. Among the multitude of chemical and physical parameters accessible by FCS are local concentrations, mobility coefficients, rate constants for association and dissociation processes, and even enzyme kinetics. As any reaction causing an alteration of the primary measurement parameters such as fluorescence brightness or mobility can be monitored, the application of this noninvasive method to unravel processes in living cells is straightforward. Due to the high spatial resolution of less than 0.5 mum, selective measurements in cellular compartments, e.g., to probe receptor-ligand interactions on cell membranes, are feasible. Moreover, the observation of local molecular dynamics provides access to environmental parameters such as local oxygen concentrations, pH, or viscosity. Thus, this versatile technique is of particular attractiveness for researchers striving for quantitative assessment of interactions and dynamics of small molecular quantities in biologically relevant systems. (C) 2003 Elsevier Science (USA). All rights reserved.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2003-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Methods
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 29 (2) Artikelnummer: - Start- / Endseite: 153 - 166 Identifikator: -