  Increasing robustness of radial GRASE acquisition for SAR-reduced brain imaging

Okanovic, M., Völker, M., Trampel, R., Breuer, F., Jakob, P., & Blaimer, M. (2018). Increasing robustness of radial GRASE acquisition for SAR-reduced brain imaging. Zeitschrift für Medizinische Physik, 28(3), 236-246. doi:10.1016/j.zemedi.2018.02.004.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel
Andere : Verbesserung der Bildqualität bei der radialen GRASE Sequenz für die SAR-reduzierte Neuro-Bildgebung

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Okanovic, Melisa1, Autor
Völker, Michael1, Autor
Trampel, Robert2, Autor           
Breuer, Felix3, Autor
Jakob, Peter1, Autor
Blaimer, Martin3, Autor
Affiliations:
1Department of Experimental Physics V, Julius Maximilian University, Würzburg, Germany, ou_persistent22              
2Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              
3Fraunhofer Institute for Integrated Circuits (IIS), Würzburg, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: SAR; High-resolution; Radial imaging; TSE
 Zusammenfassung: Purpose

To improve a radial multi-slice 2D gradient- and spin-echo (GRASE) sequence and provide an appropriate image reconstruction technique for SAR-reduced high-resolution neuroimaging.
Methods

Additional readout gradients per radio-frequency (RF) refocusing allow for a reduced number of RF pulses. In this way, a specific absorption rate (SAR) reduction is achieved and the application at high-field systems becomes more feasible. A phase insensitive image reconstruction is proposed to reduce signal dropout artifacts originating from opposite readout polarities. In addition, the image reconstruction allows for the calculation of images with varying contrast from one measurement.
Results

Results obtained at 3 T and 7 T demonstrate a SAR-reduction of at least 66% for a single-slice experiment with radial GRASE. The reduced SAR is used for an increased spatial coverage without increasing the measurement time. Experiments at 3 T and 7 T showed that the visual image quality is comparable to standard TSE and GRASE sequences with the same measurement parameters. Using higher EPI factors and the presented image reconstruction, artifact-free images with a significant SAR-reduction can be achieved.
Conclusion

Radial GRASE enables SAR-reduced acquisitions of high-resolution brain images with different contrasts from one measurement and is a promising sequence for high-field neuroimaging.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2017-07-272018-02-282018-03-232018-08
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.zemedi.2018.02.004
PMID: 29580616
Anderer: Epub 2018
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Zeitschrift für Medizinische Physik
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Jena [Germany] : Urban & Fischer
Seiten: - Band / Heft: 28 (3) Artikelnummer: - Start- / Endseite: 236 - 246 Identifikator: ISSN: 0939-3889
CoNE: https://pure.mpg.de/cone/journals/resource/110978984077161