English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  The ratio between cerebral blood flow and Tmax predicts the quality of collaterals in acute ischemic stroke

Galinovic, I., Kochova, E., Khalil, A., Villringer, K., Piper, S. K., & Fiebach, J. B. (2018). The ratio between cerebral blood flow and Tmax predicts the quality of collaterals in acute ischemic stroke. PLoS One, 13(1): e0190811. doi:10.1371/journal.pone.0190811.

Item is

Files

show Files
hide Files
:
Ganinovic_Kochova_2017.pdf (Publisher version), 4MB
Name:
Ganinovic_Kochova_2017.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Galinovic, Ivana1, Author
Kochova, Elena2, Author
Khalil, Ahmed1, 3, 4, Author           
Villringer, Kersten1, Author
Piper, Sophie K.1, 5, Author
Fiebach, Jochen B.1, Author
Affiliations:
1Center for Stroke Research, Charité University Medicine Berlin, Germany, ou_persistent22              
2International Graduate Program Medical Neurosciences, Charité University Medicine Berlin, Germany, ou_persistent22              
3Berlin School of Mind and Brain, Humboldt University Berlin, Germany, ou_persistent22              
4Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634549              
5Institute of Medical Biometrics and Clinical Epidemiology, Charité University Medicine Berlin, Germany, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Background

In acute ischemic stroke the status of collateral circulation is a critical factor in determining outcome. We propose a less invasive alternative to digital subtraction angiography for evaluating collaterals based on dynamic-susceptibility contrast magnetic resonance imaging.
Methods

Perfusion maps of Tmax and cerebral blood flow (CBF) were created for 35 patients with baseline occlusion of a major cerebral artery. Volumes of hypoperfusion were defined as having a Tmax delay of > 4 seconds (Tmax4s) and > 6 seconds (Tmax6s) and a CBF drop below 80% of healthy, contralateral tissue. For each patient a ratio between the volume of the CBF and the Tmax based perfusion deficit was calculated. Associations with collateral status and radiological outcome were assessed with the Mann-Whitney-U test, uni- and multivariable logistic regression analyses as well as area under the receiver-operator-characteristic (ROC) curve.
Results

The CBF/Tmax volume ratios were significantly associated with bad collateral status in crude logistic regression analysis as well as with adjustment for NIHSS at admission and baseline infarct volume (OR = 2.5 95% CI[1.2–5.4] p = 0.020 for CBF/Tmax 4s volume ratio and OR = 1.6 95% CI[1.0–2.6] p = 0.031 for CBF/Tmax6s volume ratio). Moreover, the ratios were significantly correlated to final infarct size (Spearman’s rho = 0.711 and 0.619, respectively for the CBF/Tmax4s volume ratio and CBF/Tmax6s volume ration, all p<0.001). The ratios also had a high area under the ROC curve of 0.93 95%CI[0.86–1.00]) and 0.90 95%CI[0.80–1.00]respectively for predicting poor radiological outcome.
Conclusions

In the setting of acute ischemic stroke the CBF/Tmax volume ratio can be used to differentiate between good and insufficient collateral circulation without the need for invasive procedures like conventional angiography.

Details

show
hide
Language(s): eng - English
 Dates: 2017-03-242017-12-202018-01-30
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1371/journal.pone.0190811
PMID: 29381701
PMC: PMC5790218
Other: eCollection 2018
 Degree: -

Event

show

Legal Case

show

Project information

show hide
Project name : -
Grant ID : 01EO0801 ; 01EO01301
Funding program : -
Funding organization : German Federal Ministry of Education and Research (BMBF)

Source 1

show
hide
Title: PLoS One
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: San Francisco, CA : Public Library of Science
Pages: - Volume / Issue: 13 (1) Sequence Number: e0190811 Start / End Page: - Identifier: ISSN: 1932-6203
CoNE: https://pure.mpg.de/cone/journals/resource/1000000000277850