  Turbulence strength in ultimate Taylor-Couette turbulence

Ezeta, R., Huisman, S. G., Sun, C., & Lohse, D. (2018). Turbulence strength in ultimate Taylor-Couette turbulence. Journal of Fluid Mechanics, 836, 397-412. doi:10.1017/jfm.2017.795.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Ezeta, R., Author
Huisman, S. G., Author
Sun, C., Author
Lohse, Detlef1, Author           
Affiliations:
1Max Planck Institute for Dynamics and Self-Organization, Max Planck Society, ou_2063285              

Content

show
hide
Free keywords: rotating turbulence; Taylor-Couette flow; turbulent convection
 Abstract: We provide experimental measurements for the effective scaling of the Taylor-Reynolds number within the bulk Re-lambda.bulk, based on local flow quantities as a function of the driving strength ( expressed as the Taylor number Ta), in the ultimate regime of Taylor-Couette flow. We define Re-lambda.bulk = (sigma(bulk) (u(theta)))(2) (15/nu epsilon(bulk)))(1/2), where sigma(bulk)(u(theta)) is the bulk-averaged standard deviation of the azimuthal velocity, epsilon(bulk) is the bulk-averaged local dissipation rate and nu is the liquid kinematic viscosity. The data are obtained through flow velocity field measurements using particle image velocimetry. We estimate the value of the local dissipation rate epsilon(r) using the scaling of the second-order velocity structure functions in the longitudinal and transverse directions within the inertial range - without invoking Taylor's hypothesis. We find an effective scaling of epsilon(bulk)/(nu(3)d(3))similar to Ta-1.40, (corresponding to Nu(omega,bulk) similar to Ta-0.40 for the dimensionless local angular velocity transfer), which is nearly the same as for the global energy dissipation rate obtained from both torque measurements (Nu(omega) similar to Ta-0.40) and direct numerical simulations (Nu(omega) similar to Ta-0.38). The resulting Kolmogorov length scale is then found to scale as eta(bulk)/d similar to Ta-0.35 and the turbulence intensity as I-theta,I-bulk similar to Ta-0.061. With both the local dissipation rate and the local fluctuations available we finally find that the Taylor-Reynolds number effectively scales as Re-lambda,Re-bulk similar to Ta-0.18 in the present parameter regime of 4.0 x 10(8) < Ta < 9.0 x 10(10).

Details

show
hide
Language(s): eng - English
 Dates: 2017-12-112018-02-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1017/jfm.2017.795
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Fluid Mechanics
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 836 Sequence Number: - Start / End Page: 397 - 412 Identifier: -