Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Online 1H-MRS measurements of time-varying lactate production in an animal model of glioma during administration of an anti-tumoral drug.

Crémillieux, Y., Salvati, R., Dumont, U., Pinaud, N., Bouchaud, V., Sanchez, S., et al. (2018). Online 1H-MRS measurements of time-varying lactate production in an animal model of glioma during administration of an anti-tumoral drug. NMR in Biomedicine, 31(2): e3861. doi:10.1002/nbm.3861.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2508814.pdf (Verlagsversion), 674KB
 
Datei-Permalink:
-
Name:
2508814.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt ( Max Planck Society (every institute); )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2508814_Suppl.doc (Ergänzendes Material), 228KB
Name:
2508814_Suppl.doc
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/msword / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Crémillieux, Y., Autor
Salvati, R., Autor
Dumont, U., Autor
Pinaud, N., Autor
Bouchaud, V., Autor
Sanchez, S., Autor
Glöggler, S.1, Autor           
Wong, A., Autor
Affiliations:
1Research Group of NMR Signal Enhancement, MPI for Biophysical Chemistry, Max Planck Society, ou_2396691              

Inhalt

einblenden:
ausblenden:
Schlagwörter: glioblastoma; in vivo MRI and MRS; lactate; metabolite profiling; microcoil; microdialysis
 Zusammenfassung: The aims of this study were to implement a magnetic resonance spectroscopy (MRS) protocol for the online profiling of subnanomolar quantities of metabolites sampled from the extracellular fluid using implanted microdialysis and to apply this protocol in glioma-bearing rats for the quantification of lactate concentration and the measurement of time-varying lactate concentration during drug administration. MRS acquisitions on the brain microdialysate were performed using a home-built, proton-tuned, microsolenoid with an active volume of 2 μL. The microcoil was placed at the outlet of the microdialysis probe inside a preclinical magnetic resonance imaging (MRI) scanner. C6-bearing rats were implanted with microdialysis probes perfused with artificial cerebrospinal fluid solution and the lactate dehydrogenase (LDH) inhibitor oxamate. Microcoil magnetic resonance spectra were continuously updated using a single-pulse sequence. Localized in vivo spectra and high-resolution spectra on the dialysate were also acquired. The limit of detection and limit of quantification per unit time of the lactate methyl peak were determined as 0.37 nmol/√min and 1.23 nmol/√min, respectively. Signal-to-noise ratios (SNRs) of the lactate methyl peak above 120 were obtained from brain tumor microdialysate in an acquisition time of 4 min. On average, the lactate methyl peak amplitude measured in vivo using the nuclear magnetic resonance (NMR) microcoil was 193 ± 46% higher in tumor dialysate relative to healthy brain dialysate. A similar ratio was obtained from high-resolution NMR spectra performed on the collected dialysate. Following oxamate addition in the perfusate, a monotonic decrease in the lactate peaks was observed in all animals with an average time constant of 4.6 min. In the absence of overlapping NMR peaks, robust profiling of extracellular lactate can be obtained online using a dedicated sensitive NMR microcoil. MRS measurements of the dynamic changes in lactate production induced by anti-tumoral drugs can be assessed accurately with temporal resolutions on the order of minutes. The MRS protocol can be readily transferred to the clinical environment with the use of suitable clinical microdialysis probes.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2017-11-292018-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/nbm.3861
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: NMR in Biomedicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: 10 Band / Heft: 31 (2) Artikelnummer: e3861 Start- / Endseite: - Identifikator: -