English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Parallel accumulation for 100% duty cycle trapped ion mobility-mass spectrometry

Silveira, J. A., Ridgeway, M. E., Laukien, F. H., Mann, M., & Park, M. A. (2017). Parallel accumulation for 100% duty cycle trapped ion mobility-mass spectrometry. International Journal of Mass Spectrometry, 413, 168-175. doi:10.1016/j.ijms.2016.03.004.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Silveira, Joshua A.1, Author
Ridgeway, Mark E.1, Author
Laukien, Frank H.1, Author
Mann, Matthias2, Author           
Park, Melvin A.1, Author
Affiliations:
1external, ou_persistent22              
2Mann, Matthias / Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565159              

Content

show
hide
Free keywords: DATA-INDEPENDENT ACQUISITION; LASER-DESORPTION IONIZATION; COLLISION CROSS-SECTIONS; ELECTROSPRAY-IONIZATION; PROTEIN COMPLEXES; FUNNEL TRAP; DISSOCIATION; SENSITIVITY; DYNAMICS; PEPTIDEPhysics; Spectroscopy; TIMS; Ion mobility-mass spectrometry; Duty cycle; Parallel accumulation; Charge capacity;
 Abstract: A new trapped ion mobility spectrometry (TIMS) apparatus has been developed and evaluated. Building on the original prototype design, the new spectrometer includes an upstream "ion accumulation trap". Inclusion of the new trap allows for storage of a population of ions during the analysis of a previously stored population of ions. By accumulating and analyzing ions in parallel, rather than in series, a duty cycle of 100% can be achieved. The new design retains the flexibility of the original design the ability to exchange mobility range, resolution, and speed/duty cycle while in all instances, maintaining superior ion utilization efficiency. When operating at 100% duty cycle, the spectrometer is shown to trap a broad range of ions (m/z 622-2722) with an average trapping efficiency of similar to 70%. Trapping efficiency was found to be constant over a range of accumulation/analysis times from 20 up to 85 ms where an average resolving power of 60 was achieved. Compared to transmission mode (MS-only) operation, the combination of high mobility resolving power, high ion utilization efficiency, and relatively fast scan times achieved with TIMS is shown to result in an improvement in mass spectral peak intensities of more than an order of magnitude. (C) 2016 Elsevier B.V. All rights reserved.

Details

show
hide
Language(s): eng - English
 Dates: 2017
 Publication Status: Issued
 Pages: 8
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: International Journal of Mass Spectrometry
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier
Pages: - Volume / Issue: 413 Sequence Number: - Start / End Page: 168 - 175 Identifier: ISSN: 1387-3806
CoNE: https://pure.mpg.de/cone/journals/resource/954926232412