de.mpg.escidoc.pubman.appbase.FacesBean
Deutsch
 
Hilfe Wegweiser Datenschutzhinweis Impressum Kontakt
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Reduction of Classical Measurement Noise via Quantum-Dense Metrology

Ast, M., Steinlechner, S., & Schnabel, R. (2016). Reduction of Classical Measurement Noise via Quantum-Dense Metrology. Physical Review Letters, 117: 180801. doi:10.1103/PhysRevLett.117.180801.

Item is

Basisdaten

einblenden: ausblenden:
Datensatz-Permalink: http://hdl.handle.net/11858/00-001M-0000-002C-3E4E-7 Versions-Permalink: http://hdl.handle.net/21.11116/0000-0000-C677-B
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1607.00130.pdf (Preprint), 836KB
Beschreibung:
File downloaded from arXiv at 2017-01-17 16:09
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
:
PRL117.180801.pdf (Verlagsversion), 906KB
 
Datei-Permalink:
-
Beschreibung:
-
Sichtbarkeit:
Eingeschränkt
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Ast, Melanie1, Autor              
Steinlechner, Sebastian1, Autor              
Schnabel, Roman1, Autor              
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, escidoc:24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Quantum Physics, quant-ph
 Zusammenfassung: Quantum-dense metrology (QDM) constitutes a special case of quantum metrology in which two orthogonal phase space projections of a signal are simultaneously sensed beyond the shot noise limit. Previously it was shown that the additional sensing channel that is provided by QDM contains information that can be used to identify and to discard corrupted segments from the measurement data. Here, we demonstrate a proof-of-principle experiment in which this information is used for improving the sensitivity without discarding any measurement segments. Our measurement reached sub-shot-noise performance although initially strong classical noise polluted the data.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2016-07-012016
 Publikationsstatus: Im Druck publiziert
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: arXiv: 1607.00130
DOI: 10.1103/PhysRevLett.117.180801
URI: http://arxiv.org/abs/1607.00130
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review Letters
  Kurztitel : Phys. Rev. Lett.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Woodbury, N.Y. : American Physical Society
Seiten: - Band / Heft: 117 Artikelnummer: 180801 Start- / Endseite: - Identifikator: ISSN: 0031-9007
CoNE: http://pubman.mpdl.mpg.de/cone/journals/resource/954925433406_1