Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  MHz ultrasound induced roughness of fluid interfaces

Boubekri, R., Gross, M., In, M., Diat, O., Nobili, M., Möhwald, H., et al. (2016). MHz ultrasound induced roughness of fluid interfaces. Langmuir, 32(40), 10177-10183. doi:10.1021/acs.langmuir.6b02167.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2354955.pdf (Verlagsversion), 2MB
 
Datei-Permalink:
-
Name:
2354955.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute of Colloids and Interfaces, MTKG; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Boubekri, Rym, Autor
Gross, Michel, Autor
In, Martin, Autor
Diat, Olivier, Autor
Nobili, Maurizio, Autor
Möhwald, Helmuth1, Autor           
Stocco, Antonio, Autor
Affiliations:
1Helmuth Möhwald, Grenzflächen, Max Planck Institute of Colloids and Interfaces, Max Planck Society, ou_1863312              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The interface between two fluids is never flat at the nanoscale, and this is important for transport across interfaces. In the absence of any external field, the surface roughness is due to thermally excited capillary waves possessing subnanometric amplitudes in the case of simple liquids. Here, we investigate the effect of ultrasound on the surface roughness of liquid–gas and liquid–liquid interfaces. Megahertz (MHz) frequency ultrasound was applied normal to the interface at relatively low ultrasonic pressures (<0.6 MPa), and the amplitudes of surface fluctuations have been measured by light reflectivity and ellipsometry. We found a dramatic enhancement of surface roughness, roughly linear with intensity, with vertical displacements of the interface as high as 50–100 nm. As a consequence, the effective contact area between two fluids can be increased by ultrasound. This result has a clear impact for enhancing interface based processes such as mass or heat transfer.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2016-09-162016
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1021/acs.langmuir.6b02167
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Langmuir
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Columbus, OH : American Chemical Society
Seiten: - Band / Heft: 32 (40) Artikelnummer: - Start- / Endseite: 10177 - 10183 Identifikator: ISSN: 0743-7463