English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Energy losses in mechanically modified bacterial magnetosomes

Molcan, M., Gojzewski, H., Skumiel, A., Dutz, S., Kovac, J., Kubovcikova, M., et al. (2016). Energy losses in mechanically modified bacterial magnetosomes. Journal of Physics D: Applied Physics, 49(36): 365002. doi:10.1088/0022-3727/49/36/365002.

Item is

Files

show Files
hide Files
:
2328491.pdf (Publisher version), 2MB
 
File Permalink:
-
Name:
2328491.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute of Colloids and Interfaces, MTKG; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Molcan, Matus, Author
Gojzewski, Hubert1, Author           
Skumiel, Andrzej, Author
Dutz, Silvio, Author
Kovac, Jozef, Author
Kubovcikova, Martina, Author
Kopcansky, Peter, Author
Vekas, Ladislau, Author
Timko, Milan, Author
Affiliations:
1Hans Riegler, Theorie & Bio-Systeme, Max Planck Institute of Colloids and Interfaces, Max Planck Society, ou_1863502              

Content

show
hide
Free keywords: -
 Abstract: Magnetosomes are isolated from the Magnetospirillum magneticum strain AMB-1 bacteria. Two samples are compared: magnetosomes normally prepared of a ‘standard’ length and magnetosomes of a short length. Chains of magnetosomes are shortened by mechanical modification (cleavage) by means of sonication treatment. They represent a new geometry of magnetosomes that have not been investigated before. The effect of the sonication is analysed using transmission and electron microscopy, atomic force microscopy, and dynamic light scattering. Scanning imaging reveals three types of shortening effect in a sample of shortened magnetosomes, namely, membrane collapse, membrane destruction, and magnetosome cleavage. Dynamic light scattering shows a reduction of hydrodynamic diameter in a sample of shortened magnetosomes. The magnetic properties of magnetosomes are analysed and compared in DC and AC magnetic fields based on the evaluation of quasi-static hysteresis loops (energy losses) and calorimetric hyperthermia measurements (specific absorption rate), respectively. A sample of shortened magnetosomes behaves magnetically in a different manner, showing that both the energy loss and the specific absorption rate are reduced, and thereby indicates a variation in the heating process. The magnetic properties of magnetosomes, together with the new and stable geometry, are balanced, which opens the way for a better adaptation of the magnetic field parameters for particular applications.

Details

show
hide
Language(s):
 Dates: 2016
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: BibTex Citekey: 0022-3727-49-36-365002
DOI: 10.1088/0022-3727/49/36/365002
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Physics D: Applied Physics
  Abbreviation : J. Phys. D: Appl. Phys.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Bristol : IOP Publishing
Pages: - Volume / Issue: 49 (36) Sequence Number: 365002 Start / End Page: - Identifier: ISSN: 0022-3727