English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Characterization and use of the spent beam for serial operation of LCLS

Boutet, S., Foucar, L., Barends, T., Botha, S., Doak, R. B., Koglin, J. E., et al. (2015). Characterization and use of the spent beam for serial operation of LCLS. Journal of Synchrotron Radiation, 22(3), 634-643. doi:10.1107/S1600577515004002.

Item is

Files

show Files
hide Files
:
JSynchrotronRad_22_2015_634.pdf (Any fulltext), 2MB
 
File Permalink:
-
Name:
JSynchrotronRad_22_2015_634.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Medical Research, MHMF; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Description:
-
OA-Status:
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Boutet, Sébastien, Author
Foucar, Lutz1, Author           
Barends, Thomas1, Author           
Botha, Sabine1, Author           
Doak, R. Bruce1, Author           
Koglin, Jason E., Author
Messerschmidt, Marc, Author
Nass, Karol1, Author           
Schlichting, Ilme1, Author           
Seibert, M. Marvin, Author
Shoeman, Robert L.1, Author           
Williams, Garth J., Author
Affiliations:
1Department of Biomolecular Mechanisms, Max Planck Institute for Medical Research, Max Planck Society, ou_1497700              

Content

show
hide
Free keywords: FEL; SFX; X-ray; multiplexing; nanocrystallography; serial femtosecond crystallography
 Abstract: X-ray free-electron laser sources such as the Linac Coherent Light Source offer very exciting possibilities for unique research. However, beam time at such facilities is very limited and in high demand. This has led to significant efforts towards beam multiplexing of various forms. One such effort involves re-using the so-called spent beam that passes through the hole in an area detector after a weak interaction with a primary sample. This beam can be refocused into a secondary interaction region and used for a second, independent experiment operating in series. The beam profile of this refocused beam was characterized for a particular experimental geometry at the Coherent X-ray Imaging instrument at LCLS. A demonstration of this multiplexing capability was performed with two simultaneous serial femtosecond crystallography experiments, both yielding interpretable data of sufficient quality to produce electron density maps

Details

show
hide
Language(s): eng - English
 Dates: 2014-12-042015-02-262015-04-112015-05-01
 Publication Status: Issued
 Pages: 10
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Synchrotron Radiation
  Abbreviation : J. Synchrotron Radiat.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Copenhagen, Denmark : Published for the International Union of Crystallography by Munksgaard
Pages: - Volume / Issue: 22 (3) Sequence Number: - Start / End Page: 634 - 643 Identifier: ISSN: 0909-0495
CoNE: https://pure.mpg.de/cone/journals/resource/954925562624