English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Automated in-chamber specimen coating for serial block-face electron microscopy

Titze, B., & Denk, W. (2013). Automated in-chamber specimen coating for serial block-face electron microscopy. Journal of Microscopy, 250(2), 101-110. doi:10.1111/jmi.12023.

Item is

Files

show Files
hide Files
:
JMicroscop_250_2013_101.pdf (Any fulltext), 2MB
 
File Permalink:
-
Name:
JMicroscop_250_2013_101.pdf
Description:
-
OA-Status:
Visibility:
Restricted (UNKNOWN id 320; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Description:
-
OA-Status:
Locator:
http://dx.doi.org/10.1111/jmi.12023 (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Titze, Benjamin1, Author           
Denk, Winfried1, Author           
Affiliations:
1Department of Biomedical Optics, Max Planck Institute for Medical Research, Max Planck Society, ou_1497699              

Content

show
hide
Free keywords: Beam deceleration; block-face imaging; charge elimination; charging; coating; SBEM; SEM
 Abstract: When imaging insulating specimens in a scanning electron microscope, negative charge accumulates locally (‘sample charging’). The resulting electric fields distort signal amplitude, focus and image geometry, which can be avoided by coating the specimen with a conductive film prior to introducing it into the microscope chamber. This, however, is incompatible with serial block-face electron microscopy (SBEM), where imaging and surface removal cycles (by diamond knife or focused ion beam) alternate, with the sample remaining in place. Here we show that coating the sample after each cutting cycle with a 1–2 nm metallic film, using an electron beam evaporator that is integrated into the microscope chamber, eliminates charging effects for both backscattered (BSE) and secondary electron (SE) imaging. The reduction in signal-to-noise ratio (SNR) caused by the film is smaller than that caused by the widely used low-vacuum method. Sample surfaces as large as 12 mm across were coated and imaged without charging effects at beam currents as high as 25 nA. The coatings also enabled the use of beam deceleration for non-conducting samples, leading to substantial SNR gains for BSE contrast. We modified and automated the evaporator to enable the acquisition of SBEM stacks, and demonstrated the acquisition of stacks of over 1000 successive cut/coat/image cycles and of stacks using beam deceleration or SE contrast.

Details

show
hide
Language(s): eng - English
 Dates: 2013-05-01
 Publication Status: Issued
 Pages: 10
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1111/jmi.12023
Other: 7904
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Microscopy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Oxford : Blackwell Science
Pages: - Volume / Issue: 250 (2) Sequence Number: - Start / End Page: 101 - 110 Identifier: ISSN: 0022-2720
CoNE: https://pure.mpg.de/cone/journals/resource/954927663105_2