Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Reduction of thermocoagulative injury via use of a picosecond infrared laser (PIRL) in laryngeal tissues

Böttcher, A., Kucher, S., Knecht, R., Jowett, N., Krötz, P., Reimer, R., et al. (2015). Reduction of thermocoagulative injury via use of a picosecond infrared laser (PIRL) in laryngeal tissues. European Archives of Oto-Rhino-Laryngology, 272(4), 941-948. doi:10.1007/s00405-015-3501-4.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Böttcher2015_Article_ReductionOfThermocoagulativeIn.pdf (Verlagsversion), 3MB
 
Datei-Permalink:
-
Name:
Böttcher2015_Article_ReductionOfThermocoagulativeIn.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Privat
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
https://dx.doi.org/10.1007/s00405-015-3501-4 (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Böttcher, Arne1, 2, Autor
Kucher, Stanislav1, 3, Autor
Knecht, Rainald1, Autor
Jowett, Nathan1, 4, Autor
Krötz, Peter5, Autor           
Reimer, Rudolph6, Autor
Schumacher, Udo7, Autor
Anders, Sven8, Autor
Münscher, Adrian1, Autor
Dalchow, Carsten V.1, Autor
Miller, R. J. Dwayne5, Autor           
Affiliations:
1Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, ou_persistent22              
2Department of Otorhinolaryngology, Head and Neck Surgery, Charite´-University Medical Center Berlin, Campus Virchow- Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany, ou_persistent22              
3Department of Prosthetic Dentistry, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, ou_persistent22              
4Department of Otolaryngology, Massachusetts Eye and Ear Infirmary and Harvard Medical School, Boston, MA, USA, ou_persistent22              
5Miller Group, Atomically Resolved Dynamics Department, Max Planck Institute for the Structure and Dynamics of Matter, Max Planck Society, ou_1938288              
6Leibniz Institute for Experimental Virology, Heinrich Pette Institute, University of Hamburg, Hamburg, Germany, ou_persistent22              
7Department of Anatomy and Experimental Morphology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, ou_persistent22              
8Department of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Laryngeal surgery; Er:YAG laser; CO2 laser; PIRL; Damage zones; Electron microscopy; Thermography
 Zusammenfassung: The carbon dioxide (CO2) laser is routinely used in glottic microsurgery for the treatment of benign and malignant disease, despite significant collateral thermal damage secondary to photothermal vaporization without thermal confinement. Subsequent tissue response to thermal injury involves excess collagen deposition resulting in scarring and functional impairment. To minimize collateral thermal injury, short-pulse laser systems such as the microsecond pulsed erbium:yttrium–aluminium-garnet (Er:YAG) laser and picosecond infrared laser (PIRL) have been developed. This study compares incisions made in ex vivo human laryngeal tissues by CO2 and Er:YAG lasers versus PIRL using light microscopy, environmental scanning electron microscopy (ESEM), and infrared thermography (IRT). In comparison to the CO2 and Er:YAG lasers, PIRL incisions showed significantly decreased mean epithelial (59.70 µm) and subepithelial (22.15 µm) damage zones (p < 0.05). Cutting gaps were significantly narrower for PIRL (133.70 µm) compared to Er:YAG and CO2 lasers (p < 0.05), which were more than 5 times larger. ESEM revealed intact collagen fibers along PIRL cutting edges without obvious carbonization, in comparison to diffuse carbonization and tissue melting seen for CO2 and Er:YAG laser incisions. IRT demonstrated median temperature rise of 4.1 K in PIRL vocal fold incisions, significantly less than for Er:YAG laser cuts (171.85 K; p < 0.001). This study has shown increased cutting precision and reduced lateral thermal damage zones for PIRL ablation in comparison to conventional CO2 and Er:YAG lasers in human glottis and supraglottic tissues.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2014-12-112015-01-032015-01-112015-04
 Publikationsstatus: Erschienen
 Seiten: 8
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1007/s00405-015-3501-4
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: European Archives of Oto-Rhino-Laryngology
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Springer Berlin Heidelberg
Seiten: - Band / Heft: 272 (4) Artikelnummer: - Start- / Endseite: 941 - 948 Identifikator: CoNE: https://pure.mpg.de/cone/journals/resource/0937-4477