Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Thermal Noise Reduction and Absorption Optimization via Multi-Material Coatings

Steinlechner, J., Martin, I. W., Hough, J., Krueger, C., Rowan, S., & Schnabel, R. (2015). Thermal Noise Reduction and Absorption Optimization via Multi-Material Coatings. Physical Review D, 042001. doi:10.1103/PhysRevD.91.042001.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1411.3150.pdf (Preprint), 586KB
Name:
1411.3150.pdf
Beschreibung:
File downloaded from arXiv at 2015-02-24 09:33
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
:
PhysRevD.91_042001.pdf (beliebiger Volltext), 447KB
Name:
PhysRevD.91_042001.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Steinlechner, Jessica, Autor
Martin, Iain W., Autor
Hough, Jim, Autor
Krueger, Christoph, Autor
Rowan, Sheila, Autor
Schnabel, Roman1, Autor           
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Physics, Optics, physics.optics
 Zusammenfassung: Future gravitational wave detectors (GWDs) such as Advanced LIGO upgrades and the Einstein Telescope are planned to operate at cryogenic temperatures using crystalline silicon (cSi) test-mass mirrors at an operation wavelength of 1550 nm. The reduction in temperature in principle provides a direct reduction in coating thermal noise, but the presently used coating stacks which are composed of silica (SiO2) and tantala (Ta2O5) show cryogenic loss peaks which results in less thermal noise improvement than might be expected. Due to low mechanical loss at low temperature amorphous silicon (aSi) is a very promising candidate material for dielectric mirror coatings and could replace Ta2O5. Unfortunately, such a aSi/SiO2 coating is not suitable for use in GWDs due to high optical absorption in aSi coatings. We explore the use of a three material based coating stack. In this multi-material design the low absorbing Ta2O5 in the outermost coating layers significantly reduces the incident light power, while aSi is used only in the lower bilayers to maintain low optical absorption. Such a coating design would enable a reduction of Brownian thermal noise by 25%. We show experimentally that an optical absorption of only (5.3 +/- 0.4)ppm at 1550 nm should be achievable.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2014-11-122015
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: arXiv: 1411.3150
DOI: 10.1103/PhysRevD.91.042001
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review D
  Andere : Phys. Rev. D.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Lancaster, Pa. : American Physical Society
Seiten: - Band / Heft: - Artikelnummer: 042001 Start- / Endseite: - Identifikator: ISSN: 0556-2821
CoNE: https://pure.mpg.de/cone/journals/resource/111088197762258