English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Real-time phase-contrast flow MRI of haemodynamic changes in the ascending aorta and superior vena cava during Mueller manoeuvre.

Fasshauer, M., Joseph, A., Kowallick, J. T., Unterberg-Buchwald, C., Merboldt, K. D., Voit, D., et al. (2014). Real-time phase-contrast flow MRI of haemodynamic changes in the ascending aorta and superior vena cava during Mueller manoeuvre. Clinical Radiology, 69(10), 1066-1071. doi:10.1016/j.crad.2014.06.004.

Item is

Files

show Files
hide Files
:
2069588.pdf (Publisher version), 809KB
Name:
2069588.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
2069588_Suppl_1.htm (Supplementary material), 51KB
Name:
2069588_Suppl_1.htm
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
text/html / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
2069588_Suppl_2.htm (Supplementary material), 51KB
Name:
2069588_Suppl_2.htm
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
text/html / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Creators

show
hide
 Creators:
Fasshauer, M., Author
Joseph, A.1, Author           
Kowallick, J. T., Author
Unterberg-Buchwald, C., Author
Merboldt, K. D., Author
Voit, D.1, Author           
Steinmetz, M., Author
Staab, W., Author
Schätz, S.1, Author           
Zhang, S.1, Author           
Frahm, J.1, Author           
Lotz, J., Author
Sohns, J. M., Author
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Content

show
hide
Free keywords: -
 Abstract: AIM: To evaluate the potential of real-time phase-contrast flow magnetic resonance imaging (MRI) at 40 ms resolution for the simultaneous determination of blood flow in the ascending aorta (AA) and superior vena cava (SVC) in response to reduced intrathoracic pressure (Mueller manoeuvre). MATERIALS AND METHODS: Through-plane flow was assessed in 20 healthy young subjects using real-time phase-contrast MRI based on highly undersampled radial fast low-angle shot (FLASH) with image reconstruction by regularized non-linear inversion. Haemodynamic alterations (three repetitions per subject = 60 events) were evaluated during normal breathing (10 s), inhalation with nearly closed epiglottis (10 s), and recovery (20 s). RESULTS: Relative to normal breathing and despite interindividual differences, reduced intrathoracic pressure by at least 30 mmHg significantly decreased the initial peak mean velocity (averaged across the lumen) in the AA by -24 +/- 9% and increased the velocity in the SVC by +28 +/- 25% (p < 0.0001, n = 23 successful events). Respective changes in flow volume per heartbeat were -25 +/- 9% in the AA and +49 +/- 44% in the SVC (p < 0.0001, n = 23). Flow parameters returned to baseline during sustained pressure reduction, while the heart rate was elevated by 10% (p < 0.0001) after the start (n = 24) and end (n = 17) of the manoeuvre. CONCLUSIONS: Real-time flow MRI during low intrathoracic pressure non-invasively revealed quantitative haemodynamic adjustments in both the AA and SVC. (C) 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Details

show
hide
Language(s): eng - English
 Dates: 2014-07-222014-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.crad.2014.06.004
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Clinical Radiology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 69 (10) Sequence Number: - Start / End Page: 1066 - 1071 Identifier: -