Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Correction of gradient-induced phase errors in radial MRI.

Moussavi, A., Untenberger, M., Uecker, M., & Frahm, J. (2014). Correction of gradient-induced phase errors in radial MRI. Magnetic Resonance in Medicine, 71(1), 308-312. doi:10.1002/mrm.24643.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1900318.pdf (Verlagsversion), 316KB
 
Datei-Permalink:
-
Name:
1900318.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Moussavi, A.1, Autor           
Untenberger, M.1, Autor           
Uecker, M.1, Autor           
Frahm, J.1, Autor           
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Inhalt

einblenden:
ausblenden:
Schlagwörter: real-time MRI; eddy currents; phase errors; radial MRI
 Zusammenfassung: Purpose To correct gradient-induced phase errors in radial MRI. Methods Gradient-induced eddy currents affect the MRI data acquisition by gradient delays and phase errors that may lead to severe image artifacts for non-Cartesian imaging scenarios such as radial trajectories. While gradient delays are dealt with by respective shifts of the acquisition window during radial image acquisition, this work introduces a simple method for quantifying and correcting phase errors from the actual data prior to image reconstruction. For a given gradient system, the approach yields a specific phase error per gradient that can be used for correcting the raw data. Results Phantom studies at 9.4 T demonstrated marked improvements in radial image quality. It could be shown that the phase correction is not compromised by data undersampling. Moreover, the selective correction of gradient-induced phase errors retained the phase information caused by different concentrations of a paramagnetic contrast agent. Conclusion The proposed method does not require additional reference measurements and separately corrects for phase errors induced by eddy currents, while retaining the residual phase of the object which may carry physiologic information.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-02-252014-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.24643
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 71 (1) Artikelnummer: - Start- / Endseite: 308 - 312 Identifikator: ISSN: 0740-3194