English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Impact of image acquisition on voxel-based morphometry investigations of age-related structural brain changes

Streitbürger, D. P., Pampel, A., Krueger, G., Lepsien, J., Schroeter, M. L., Mueller, K., et al. (2014). Impact of image acquisition on voxel-based morphometry investigations of age-related structural brain changes. NeuroImage, 87, 170-182. doi:10.1016/j.neuroimage.2013.10.051.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Streitbürger, Daniel Paolo1, Author           
Pampel, André1, Author           
Krueger, Gunnar2, Author
Lepsien, Jöran1, Author           
Schroeter, Matthias L.3, Author           
Mueller, Karsten1, Author           
Möller, Harald E.1, Author           
Affiliations:
1Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              
2Siemens Schweiz AG, Healthcare Sector IM & WS, Renens, Switzerland, ou_persistent22              
3Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634549              

Content

show
hide
Free keywords: Aging; Imaging pulse sequence; Radiofrequency coil; Voxel size; Voxel-based morphometry
 Abstract: A growing number of magnetic resonance imaging studies employ voxel-based morphometry (VBM) to assess structural brain changes. Recent reports have shown that image acquisition parameters may influence VBM results. For systematic evaluation, gray-matter-density (GMD) changes associated with aging were investigated by VBM employing acquisitions with different radiofrequency head coils (12-channel matrix coil vs. 32-channel array), different pulse sequences (MP-RAGE vs. MP2RAGE), and different voxel dimensions (1 mm vs. 0.8 mm). Thirty-six healthy subjects, classified as young, middle-aged, or elderly, participated in the study. Two-sample and paired t-tests revealed significant effects of acquisition parameters (coil, pulse sequence, and resolution) on the estimated age-related GMD changes in cortical and subcortical regions. Potential advantages in tissue classification and segmentation were obtained for MP2RAGE. The 32-channel coil generally outperformed the 12-channel coil, with more benefit for MP2RAGE. Further improvement can be expected from higher resolution if the loss in SNR is accounted for. Use of inconsistent acquisition parameters in VBM analyses is likely to introduce systematic bias. Overall, acquisition and protocol changes require careful adaptations of the VBM analysis strategy before generalized conclusion can be drawn.

Details

show
hide
Language(s): eng - English
 Dates: 2013-10-242013-11-022014-02-15
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.neuroimage.2013.10.051
PMID: 24188812
Other: Epub 2013
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: NeuroImage
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 87 Sequence Number: - Start / End Page: 170 - 182 Identifier: ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166