English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Effect of the homogeneity of the column set on the performance of a simulated moving bed unit. Part I: Theory

Mihlbachler, K., Fricke, J., Yun, T., Seidel-Morgenstern, A., Schmidt-Traub, H., & Guiochon, G. (2001). Effect of the homogeneity of the column set on the performance of a simulated moving bed unit. Part I: Theory. Journal of Chromatography A, 908(1-2), 49-70. doi:10.1016/S0021-9673(00)00935-3.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Mihlbachler, K., Author
Fricke, J., Author
Yun, T., Author
Seidel-Morgenstern, A.1, 2, Author           
Schmidt-Traub, H., Author
Guiochon, G., Author
Affiliations:
1Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
2Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              

Content

show
hide
Free keywords: -
 Abstract: Although it is impossible to manufacture identical columns for use in a simulated moving bed (SMB) process, theoretical studies assume that all the columns in a SMB unit have identical characteristics. In practice, calculations in modeling and optimization studies are made with the average values of each column parameter set. In this report, the effects on SMB process performance caused by column-to-column fluctuations of the parameters are discussed. As a first step, we show how the differences in porosity of the columns may be taken into account with a revised set of separation conditions. Reductions in the purity of the extract and the raffinate streams are quantitatively related to the column-to-column fluctuations of the retention times of the two components arising from these porosity differences. For the sake of simplicity, the discussion first addresses the case of a four-column SMB operating under linear conditions. Then, the scope is extended to the cases of SMB units incorporating several columns in each section and to SMB units operating under nonlinear conditions. © 2001 Elsevier Science B.V. [accessed 2013 November 29th]

Details

show
hide
Language(s):
 Dates: 2001
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 63060
DOI: 10.1016/S0021-9673(00)00935-3
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Chromatography A
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier
Pages: - Volume / Issue: 908 (1-2) Sequence Number: - Start / End Page: 49 - 70 Identifier: ISSN: 0021-9673
CoNE: https://pure.mpg.de/cone/journals/resource/954925527837_1