Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Nonlinear frequency response functions of a chromatographic column : A critical evaluation of their potential for estimation of single solute adsorption isotherms

Ilic, M., Petkovska, M., & Seidel-Morgenstern, A. (2007). Nonlinear frequency response functions of a chromatographic column: A critical evaluation of their potential for estimation of single solute adsorption isotherms. Chemical Engineering Science, 62(5), 1269-1281. doi:10.1016/j.ces.2006.11.019.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Ilic, M.1, Autor           
Petkovska, M.2, Autor
Seidel-Morgenstern, A.1, 3, Autor           
Affiliations:
1Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
2University of Belgrade, Department of Chemical Engineering, Faculty of Technology and Metallurgy, Belgrade, Serbia , ou_persistent22              
3Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Adsorption; Chromatography; Isotherms; Frequency response; Nonlinear dynamics; Parameter identification
 Zusammenfassung: Nonlinear frequency response analysis is applied to study single component adsorption in chromatographic columns. Single component adsorption isotherms can be estimated from local derivatives of the adsorption isotherm at specified steady-state concentrations, which are obtained from the low frequency asymptotic behaviour of the higher order frequency response functions (FRFs) of a chromatographic column. The functions relevant for the estimation of adsorption isotherms are the phases and the first derivatives of these FRFs. These functions (up to the third order) are analyzed for different types of adsorption isotherm models, different isotherm parameters, steady-state concentrations and numbers of theoretical plates of the chromatographic column. Based on this analysis, some unified characteristics of these functions are observed, which can be used for critical evaluation of the method and to design efficient experimental procedures for its application. Advantages and limitations of this method are discussed. Copyright © 2013 Elsevier B.V. [accessed 2013 November 26th]

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2007
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 290752
DOI: 10.1016/j.ces.2006.11.019
Anderer: 3/07
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Chemical Engineering Science
  Andere : Chem. Eng. Sci.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : Pergamon
Seiten: - Band / Heft: 62 (5) Artikelnummer: - Start- / Endseite: 1269 - 1281 Identifikator: ISSN: 0009-2509