English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Preparative separation of multi-component mixtures using stationary phase gradients

Sreedhar, B., & Seidel-Morgenstern, A. (2008). Preparative separation of multi-component mixtures using stationary phase gradients. Journal of Chromatography A, 1215(1-2), 133-144. doi:10.1016/j.chroma.2008.11.003.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Sreedhar, B.1, 2, Author           
Seidel-Morgenstern, A.1, 3, Author           
Affiliations:
1Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
2International Max Planck Research School (IMPRS), Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, DE, ou_1738143              
3Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              

Content

show
hide
Free keywords: Preparative chromatography; Stationary phase gradient; Equilibrium dispersive model; Multiple stationary phases; Genetic algorithm
 Abstract: Solvent gradients have been widely applied in analytical and preparative chromatography to enhance selectivity and improve productivity. Recently, an alternative concept using solid phase gradients was introduced in analytical chromatography [Nyiredy, Szucs, Szepesy, Chromatographia 63 (2006) 3; Nyiredy, Szucs, Szepesy, J. Chromatogr. A 1157 (2007) 122]. This concept is based on connecting columns filled with different stationary phases in series, applying a constant mobile phase composition. With the availability of column connecting devices with low dead volumes [K. Bischoff, S. Nyiredy, Z. Szücs, Elements for separating substances by distributing between a stationary and a mobile phase, and method for the production of a separating device. WO/2006/125564; PCT/EP2006/004744, 2006.], the concept can be easily implemented. The application of sequentially connected columns with different properties introduces new degrees of freedom like the type, number, relative lengths and positions of individual segments. In this study, an attempt is made to analyze if such stationary phase gradients could be exploited favorably in preparative chromatography for separating multi-component mixtures. A theoretical study is carried out for a connection of two different types of column segments based on numerical solutions of the equilibrium dispersive model assuming specific adsorption isotherm parameters for each segment. The influence of relative segment lengths and the order of the arrangement are evaluated with respect to the performance of separating intermediately eluting components from multi-component mixtures. Copyright © 2008 Elsevier B.V. All rights reserved. [accessed November 26th 2013]

Details

show
hide
Language(s): eng - English
 Dates: 2008
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 395661
DOI: 10.1016/j.chroma.2008.11.003
Other: 29/08
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Chromatography A
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier
Pages: - Volume / Issue: 1215 (1-2) Sequence Number: - Start / End Page: 133 - 144 Identifier: ISSN: 0021-9673
CoNE: https://pure.mpg.de/cone/journals/resource/954925527837_1