English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Atmospheric Pressure Free Liquid Infrared MALDI Mass Spectrometry : Toward a combined ESI/MALDI-Liquid Chromatography Interface

Rapp, E., Charvat, A., Beinsen, A., Plessmann, U., Reichl, U., Seidel-Morgenstern, A., et al. (2009). Atmospheric Pressure Free Liquid Infrared MALDI Mass Spectrometry: Toward a combined ESI/MALDI-Liquid Chromatography Interface. Analytical Chemistry, 81(1), 443-452. doi:10.1021/ac801863p.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Rapp, E.1, Author           
Charvat, A.2, Author           
Beinsen, A.3, Author
Plessmann, U.4, Author           
Reichl, U.1, 5, Author           
Seidel-Morgenstern, A.5, 6, Author           
Urlaub, H.4, Author           
Abel, B.3, 7, Author
Affiliations:
1Bioprocess Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738140              
2Department of Spectroscopy and Photochemical Kinetics, MPI for biophysical chemistry, Max Planck Society, ou_578624              
3Georg-August University of Göttingen, Institute for Physical Chemistry, Göttingen, Germany, ou_persistent22              
4Research Group of Bioanalytical Mass Spectrometry, MPI for biophysical chemistry, Max Planck Society, ou_578613              
5Otto-von-Guericke-Universität Magdeburg, ou_1738156              
6Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
7University Leipzig, W.-Ostwald-Institute for Physical and Theoretical Chemistry, Germany, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: A new atmospheric pressure (AP)-MALDI-type interface has been developed based on a free liquid (FL) microbeam/microdroplets and a mid-infrared optical parametric oscillator (mid-IR OPO). The device is integrated into a standard on-line nanoESI interface. The generation of molecular ions in the gas phase is believed to be the result of a fast (explosive) laser-induced evaporative dispersion (not desorption) of the microbeam into statistically charged nanodroplets. Only the lowest charge states appear in significant abundance in this type of experiment. Mass spectra of some common peptides have been acquired in positive ion mode, and the limit-of-detection of this first prototype (liquid microbeam setup) was evaluated to be 17 fmol per second. To improve the duty cycle and to reduce the sample consumption, a droplet-on-demand system was implemented (generating 100 pL droplets). With this setup, about 20 attomole of bradykinin were sufficient to achieve a signal-to-noise ratio better than five. This setup can be operated at flow rates down to 100 nL/min and represents a liquid MALDI alternative to the nanoESI. Our particular interest was the application of the developed ion source for on-line coupling of liquid chromatography with mass spectrometry. The flow rates (>100 μL/min), required for stable operation of the ion source in continuous liquid microbeam mode, matches perfectly the flow rate range of microHPLC. Therefore, on-line LC/MS experiments have been realized, employing a microbore C18 reversed-phase column to separate an artificial peptide mixture and tryptic peptides of bovine serum albumin (performing a peptide mass fingerprint). In the latter case, sequence coverage of more than 90% has been achieved. Copyright © 2008 American Chemical Society [accessed January 29, 2009]

Details

show
hide
Language(s): eng - English
 Dates: 2009
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 395881
DOI: 10.1021/ac801863p
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Analytical Chemistry
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Washington, D.C. : American Chemical Society
Pages: - Volume / Issue: 81 (1) Sequence Number: - Start / End Page: 443 - 452 Identifier: ISSN: 0003-2700
CoNE: https://pure.mpg.de/cone/journals/resource/111032812862552