de.mpg.escidoc.pubman.appbase.FacesBean
English
 
HelpDisclaimerContact usLogin
  Advanced SearchBrowse

Item

  Cryogenic linear Paul trap for cold highly charged ion experiments

Schwarz, M., Versolato, O., Windberger, A., Brunner, F. R., Ballance, T., Eberle, S. N., et al. (2012). Cryogenic linear Paul trap for cold highly charged ion experiments. Review of scientific instruments, 83(8), 1-10. doi:http://link.aip.org/link/doi/10.1063/1.4742770.

Item is

Basic

show hide
Bookmark this item: http://pubman.mpdl.mpg.de/pubman/item/escidoc:1544169:4
Genre: Journal Article

Files

show Files

Locators

show
hide
Locator:
http://link.aip.org/link/doi/10.1063/1.4742770 (Publisher version)
Description:
-

Creators

show
hide
 Creators:
Schwarz, M.1, Author              
Versolato, Oscar1, Author              
Windberger, Alexander1, Author              
Brunner, F. R.1, Author
Ballance, T.1, Author
Eberle, S. N.1, Author
Ullrich, J.1, Author              
Schmidt, P. O.2, Author
Hansen, A. K.2, Author
Gingell, A. D.2, Author
Drewsen, M.2, Author
Crespo López Urrutia, J. R.1, Author              
Affiliations:
1Division Prof. Dr. Joachim H. Ullrich, MPI for Nuclear Physics, Max Planck Society, escidoc:904547              
22University of Groningen, Kernfysisch Versneller Instituut, NL-9747 AA Groningen, The Netherlands 3Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany 4Institut für Quantenoptik, Leibniz Universität Hannover, Welfengarten 1, 30167 Hannover, Germany 5Department of Physics and Astronomy, University of Aarhus, DK-8000 Aarhus C, Denmark , escidoc:persistent22              

Content

show
hide
Free keywords: beryllium, cryogenics, particle traps, positive ions, trapped ions  
 Abstract: Storage and cooling of highly charged ions require ultra-high vacuum levels obtainable by means of cryogenic methods. We have developed a linear Paul trap operating at 4 K capable of very long ion storage times of about 30 h. A conservative upper bound of the H2 partial pressure of about 10−15 mbar (at 4 K) is obtained from this. External ion injection is possible and optimized optical access for lasers is provided, while exposure to black body radiation is minimized. First results of its operation with atomic and molecular ions are presented. An all-solid state laser system at 313 nm has been set up to provide cold Be+ ions for sympathetic cooling of highly charged ions.

Details

show
hide
Language(s): eng - English
 Dates: 2012-07-112012-08-27
 Pages: 10
 Publishing info: -
 Table of Contents: -
 Rev. Method: Peer
 Degree: -

Event

show

Legal Case

show

Source 1

show
hide
Title: Review of scientific instruments
Source Genre: Journal
 Creator(s):
-
Affiliations:
-
Publ. Info: Woodbury, N.Y. [etc.] : American Institute of Physics
Pages: - Volume / Issue: 83 (8) Sequence Number: 083115 Start / End Page: 1 - 10 Identifier: ISSN: 0034-6748
CoNE: http://pubman.mpdl.mpg.de/cone/journals/resource/991042742033452