de.mpg.escidoc.pubman.appbase.FacesBean
Deutsch
 
Hilfe Wegweiser Datenschutzhinweis Impressum Kontakt
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Sensitive detection of Doppler-free two-photon-excited 2S positronium by spatially separated photoionization

Fee, M. S., Mills, A. P., Shaw, E. D., Chichester, R. J., Zuckerman, D. M., Chu, S., et al. (1991). Sensitive detection of Doppler-free two-photon-excited 2S positronium by spatially separated photoionization. Physical Review A, 44(1), R5-R8. doi:10.1103/PhysRevA.44.R5.

Item is

Basisdaten

einblenden: ausblenden:
Datensatz-Permalink: http://hdl.handle.net/11858/00-001M-0000-0013-5CB8-0 Versions-Permalink: http://hdl.handle.net/11858/00-001M-0000-0013-5CB9-E
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
372217.pdf (Verlagsversion), 794KB
Beschreibung:
-
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Fee, Michale S.1, Autor
Mills, A. P., Autor
Shaw, E. D., Autor
Chichester, R. J., Autor
Zuckerman, D. M., Autor
Chu, Steven, Autor
Danzmann, Karsten2, Autor              
Affiliations:
1External Organizations, escidoc:persistent13              
2Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, escidoc:24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Using a spatially filtered pulsed laser at 486 nm we have photoexcited positronium to the 2S state and detected it via a delayed and spatially separated 532-nm photoionization pulse. We have extended our observations down to low 486-nm power to explore the possibility of a cw measurement of the positronium 1S-2S interval. A model calculation taking into account the velocity distribution of the 235-K positronium from an oxygenated cold Al(111) target, the parameters of the laser beams, and the nonlinear excitation probability explains our data. The same model indicates that a cw measurement is presently feasible.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 1991-07
 Publikationsstatus: Im Druck publiziert
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review A
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 44 (1) Artikelnummer: - Start- / Endseite: R5 - R8 Identifikator: ISSN: 1094-1622