Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Calibration of GEO 600 for the S1 science run

Hewitson, M., Grote, H., Heinzel, G., Strain, K. A., Ward, H., & Weiland, U. (2003). Calibration of GEO 600 for the S1 science run. Classical and Quantum Gravity, 20(17), 885-893.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
59878.pdf (Verlagsversion), 252KB
Name:
59878.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Hewitson, Martin1, Autor           
Grote, Hartmut2, Autor           
Heinzel, Gerhard2, Autor           
Strain, Kenneth A.2, 3, Autor
Ward, H.2, 3, Autor
Weiland, Uta2, 3, Autor
Affiliations:
1Observational Relativity and Cosmology, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24011              
2Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              
3AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24009              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: In 2002, the interferometric gravitational wave detector GEO 600 took part in a coincident science run (S1) with other detectors world-wide. When completed, GEO will employ a dual-recycling scheme which will allow its peak sensitivity to be tuned over a range of frequencies in the detection band. Still in the commissioning phase, GEO was operated as a power-recycled Michelson for the duration of S1. The accurate calibration of the sensitivity of GEO to gravitational waves is a critical step in preparing GEO data for exchange with other detectors forming a world-wide detector network. An online calibration scheme has been developed to perform real-time calibration of the power-recycled GEO detector. This scheme will later be extended to cover the more complex case of the dual-recycled interferometer in which multiple output signals will need to be combined to optimally recover a calibrated strain channel. This report presents an outline of the calibration scheme that was used during S1. Also presented are results of detector characterization work that arises naturally from the calibration work.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2003-09-07
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 59878
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Classical and Quantum Gravity
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 20 (17) Artikelnummer: - Start- / Endseite: 885 - 893 Identifikator: -