  Mechanical quality factor measurements of monolithically-suspended fused silica test masses of the GEO600 gravitational wave detector

Smith, J. R., Cagnoli, G., Crooks, D. R. M., Fejer, M. M., Gossler, S., Lück, H., et al. (2004). Mechanical quality factor measurements of monolithically-suspended fused silica test masses of the GEO600 gravitational wave detector. Classical Quantum Gravity, 21(5), S1091-S1098.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
118609.pdf (Verlagsversion), 105KB
Name:
118609.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Smith, Joshua R.1, 2, Autor
Cagnoli, G.1, 2, Autor
Crooks, D. R. M.1, 2, Autor
Fejer, M. M.1, 2, Autor
Gossler, Stefan2, Autor           
Lück, Harald2, Autor           
Rowan, S.1, 2, Autor
Hough, Jim1, 2, Autor
Danzmann, Karsten2, Autor           
Affiliations:
1AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24009              
2Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Internal thermal noise is expected to be a limiting noise source in the most sensitive frequency band of the GEO 600 gravitational wave detector. Because thermal noise is directly related to energy dissipation, care has been taken to construct test mass suspensions from low-dissipation materials and to eliminate inter-material rubbing where possible. Recently, the GEO 600 team finished the installation of triple-pendulum suspensions for the optics of the Michelson interferometer. Each of these triple pendulums incorporates a monolithic fused silica pendulum as the lowest stage. We have made internal mode quality factor measurements of three monolithically suspended test masses. Using these measurements we estimate of the level of internal thermal noise in the GEO 600 interferometer.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2004-03-07
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 118609
DOI: 10.1088/0264-9381/21/5/105
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 5th Edoardo Amaldi Conference on Gravitational Waves
Veranstaltungsort: Tirrenia, Italy
Start-/Enddatum: 2003-07-06 - 2003-07-11

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Classical Quantum Gravity
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 21 (5) Artikelnummer: - Start- / Endseite: S1091 - S1098 Identifikator: ISSN: 0264-9381