Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Coherent Control of Vacuum Squeezing in the Gravitational-Wave Detection Band

Vahlbruch, H., Chelkowski, S., Hage, B., Franzen, A., Danzmann, K., & Schnabel, R. (2006). Coherent Control of Vacuum Squeezing in the Gravitational-Wave Detection Band. Physical Review Letters, 97: 011101. doi:10.1103/PhysRevLett.97.011101.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
PRL97_011101.pdf (Verlagsversion), 324KB
Name:
PRL97_011101.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-
:
vahlbruch02.pdf (beliebiger Volltext), 372KB
Name:
vahlbruch02.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Vahlbruch, Henning1, Autor           
Chelkowski, Simon1, 2, Autor
Hage, Boris1, Autor           
Franzen, Alexander1, 2, Autor
Danzmann, Karsten1, Autor           
Schnabel, Roman1, Autor           
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              
2AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24009              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: We propose and demonstrate a coherent control scheme for stable phase locking of squeezed vacuum fields. We focus on sideband fields at frequencies from 10 Hz to 10 kHz, which is a frequency regime of particular interest in gravitational-wave detection and for which conventional control schemes have failed so far. A vacuum field with broadband squeezing covering this entire band was produced using optical parametric oscillation and characterized with balanced homodyne detection. The system was stably controlled over long periods utilizing two coherent but frequency shifted control fields. In order to demonstrate the performance of our setup the squeezed field was used for a nonclassical sensitivity improvement of a Michelson interferometer at audio frequencies.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2006-07
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 286675
DOI: 10.1103/PhysRevLett.97.011101
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review Letters
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 97 Artikelnummer: 011101 Start- / Endseite: - Identifikator: -