Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Thermal diagnostic of the optical window on board LISA Pathfinder

Nofrarias, M., Garcia Marin, A. F., Lobo, A., Heinzel, G., Ramos-Castro, J., Sanjuan, J., et al. (2007). Thermal diagnostic of the optical window on board LISA Pathfinder. Classical and Quantum Gravity, 24(20), 5103-5121. doi:10.1088/0264-9381/24/20/012.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
cqg7_20_012.pdf (Verlagsversion), 691KB
Name:
cqg7_20_012.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-
:
0709.0442v1.pdf (Preprint), 851KB
Name:
0709.0442v1.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Nofrarias, Miquel1, Autor           
Garcia Marin, A. F.1, Autor           
Lobo, Alberto, Autor
Heinzel, Gerhard1, Autor           
Ramos-Castro, J., Autor
Sanjuan, J., Autor
Danzmann, Karsten1, Autor           
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Vacuum conditions inside the LTP Gravitational Reference Sensor must comply with rather demanding requirements. The Optical Window (OW) is an interface which seals the vacuum enclosure and, at the same time, lets the laser beam go through for interferometric Metrology with the test masses. The OW is a plane-parallel plate clamped in a Titanium flange, and is considerably sensitive to thermal and stress fluctuations. It is critical for the required precision measurements, hence its temperature will be carefully monitored in flight. This paper reports on the results of a series of OW characterisation laboratory runs, intended to study its response to selected thermal signals, as well as their fit to numerical models, and the meaning of the latter. We find that a single pole ARMA transfer function provides a consistent approximation to the OW response to thermal excitations, and derive a relationship with the physical processes taking place in the OW. We also show how system noise reduction can be accomplished by means of that transfer function.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2007-10-21
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 335031
ISI: 000249987800013
Anderer: arXiv:0709.0442
DOI: 10.1088/0264-9381/24/20/012
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Classical and Quantum Gravity
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 24 (20) Artikelnummer: - Start- / Endseite: 5103 - 5121 Identifikator: ISSN: 0264-9381