English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  The GEO600 project

Lück, H., & GEO600 Team (1997). The GEO600 project. Classical and quantum gravity, 14(6), 1471-1476. doi:10.1088/0264-9381/14/6/012.

Item is

Files

show Files
hide Files
:
0264-9381_14_6_012.pdf (Any fulltext), 246KB
Name:
0264-9381_14_6_012.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Lück, Harald1, Author           
GEO600 Team, Author
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Content

show
hide
Free keywords: -
 Abstract: GEO600, an interferometric gravitational-wave detector with an arm length of 600 m, is currently being built in northern Germany close to Hannover. GEO600 incorporates an externally modulated fourfold delay-line Michelson interferometer giving a round-trip optical length of 2400 m. A master - slave combination of a monolithic diode-pumped Nd:YAG ring laser and an injection-locked amplifier will give a light power of about 10 W at a wavelength of 1064 nm. Power recycling increases the light power inside the interferometer to a level of about 10 kW. The use of both power and signal recycling will yield a sensitivity of the same order of magnitude as the first stages of the other large-scale gravitational-wave detectors LIGO and VIRGO currently under construction. High signal recycling factors allow the sensitivity to be increased at a chosen frequency while reducing the bandwidth of the detector. This gives an advantage over broad-band detectors in detecting narrow-band periodic sources such as pulsars. The 25 cm diameter mirrors will be suspended as double pendulums from a platform supported by vibration-reduction systems. The passive filtering properties of this system sufficiently reduce the seismic noise in the frequency range of interest, i.e. 50 - 1000 Hz. The detector will start taking data in the year 2000.

Details

show
hide
Language(s):
 Dates: 1997-06
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1088/0264-9381/14/6/012
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Classical and quantum gravity
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Bristol, U.K. : Institute of Physics
Pages: - Volume / Issue: 14 (6) Sequence Number: - Start / End Page: 1471 - 1476 Identifier: ISSN: 0264-9381
CoNE: https://pure.mpg.de/cone/journals/resource/954925513480_1