Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Beating the standard sensitivity-bandwidth limit of cavity-enhanced interferometers with internal squeezed-light generation

Korobko, M., Kleybolte, L., Ast, S., Miao, H., Chen, Y., & Schnabel, R. (2017). Beating the standard sensitivity-bandwidth limit of cavity-enhanced interferometers with internal squeezed-light generation. Physical Review Letters, 118: 143601. doi:10.1103/PhysRevLett.118.143601.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1702.01044.pdf (Preprint), 2MB
Name:
1702.01044.pdf
Beschreibung:
File downloaded from arXiv at 2017-03-14 11:11
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
:
PRL118.143601.pdf (Verlagsversion), 667KB
 
Datei-Permalink:
-
Name:
PRL118.143601.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Gravitational Physics (Albert Einstein Institute), MPGR; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
American Physical Society
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Korobko, Mikhail, Autor
Kleybolte, Lisa, Autor
Ast, Stefan1, Autor           
Miao, Haixing, Autor
Chen, Yanbei, Autor
Schnabel, Roman, Autor
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Quantum Physics, quant-ph,General Relativity and Quantum Cosmology, gr-qc
 Zusammenfassung: The shot-noise limited peak sensitivity of cavity-enhanced interferometric measurement devices, such as gravitational-wave detectors, can be improved by increasing the cavity finesse, even when comparing fixed intra-cavity light powers. For a fixed light power inside the detector, this comes at the price of a proportional reduction in the detection bandwidth. High sensitivity over a large span of signal frequencies, however, is essential for astronomical observations. It is possible to overcome this standard sensitivity-bandwidth limit using non-classical correlations in the light field. Here, we investigate the internal squeezing approach, where the parametric amplification process creates a non-classical correlation directly inside the interferometer cavity. We analyse the limits of the approach theoretically, and measure 36% increase in the sensitivity-bandwidth product compared to the classical case. To our knowledge this is the first experimental demonstration of an improvement in the sensitivity-bandwidth product using internal squeezing, opening the way for a new class of optomechanical force sensing devices.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2017-02-032017-02-132017
 Publikationsstatus: Erschienen
 Seiten: 5 pages, 3 figures
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review Letters
  Kurztitel : Phys. Rev. Lett.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Woodbury, N.Y. : American Physical Society
Seiten: - Band / Heft: 118 Artikelnummer: 143601 Start- / Endseite: - Identifikator: ISSN: 0031-9007
CoNE: https://pure.mpg.de/cone/journals/resource/954925433406_1