Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Online normal-phase high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometry: Effects of different ionization methods on the characterization of highly complex crude oil mixtures

Lababidi, S., & Schrader, W. (2014). Online normal-phase high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometry: Effects of different ionization methods on the characterization of highly complex crude oil mixtures. Rapid Communications in Mass Spectrometry, 28(12), 1345-1352. doi:10.1002/rcm.6907.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Lababidi, Sami1, Autor           
Schrader, Wolfgang1, Autor           
Affiliations:
1Service Department Schrader (MS), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445629              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: RATIONALE Characterization of crude oil represents a challenge for researchers due to its complexity. While Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is the method of choice for such complex matrices the high number of ions present limits the efficiency of the analysis due to charge competition and space charge effects. One way to solve this problem is the direct coupling of FT-ICR MS with high-performance liquid chromatography (HPLC). METHODS Normal-phase liquid chromatography was applied on a deasphalted crude oil sample by using a polar aminocyano-bonded stationary phase with n-hexane and isopropyl alcohol as a mobile phase. The HPLC system was coupled online to a 12 T ultrahigh-resolution FT-ICR mass spectrometer. Ion chromatograms were obtained with electrospray ionization (ESI), atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure laser ionization (APLI). RESULTS The chromatographic separation yielded a group separation into two peaks according to the polarity of the components. Each ionization technique was able to uniquely assign components differing in polarity and aromaticity. Additionally, an increase in aromaticity in the course of retention time for nonpolar species in the first peak was observed. Monitoring the ratio between protonated and radical mono-nitrogen species was achieved. CONCLUSIONS For the analysis of a crude oil sample, online coupling of a normal-phase HPLC system to an FT-ICR mass spectrometer was achieved. The results of the different ionization techniques were compared with each other, which enables a detailed characterization of the complex sample.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2014-05-042014-06-30
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/rcm.6907
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Rapid Communications in Mass Spectrometry
  Andere : Rapid Commun. Mass Spectrom.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : John Wiley & Sons
Seiten: - Band / Heft: 28 (12) Artikelnummer: - Start- / Endseite: 1345 - 1352 Identifikator: ISSN: 0951-4198
CoNE: https://pure.mpg.de/cone/journals/resource/954925574961