  Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment

The XENON100 Collabration, Aprile, E., Agostini, F., Alfonsi, M., Arisaka, K., Arneodo, F., et al. (2014). Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment. Journal of Instrumentation, 9(11): P11006. doi:10.1088/1748-0221/9/11/P11006.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1406.2374.pdf (Preprint), 952KB
Name:
1406.2374.pdf
Beschreibung:
File downloaded from arXiv at 2015-01-23 12:37
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://iopscience.iop.org/1748-0221/9/11/P11006 (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
The XENON100 Collabration, Autor              
Aprile, E., Autor
Agostini, F., Autor
Alfonsi, M., Autor
Arisaka, K., Autor
Arneodo, F., Autor
Auger, M., Autor
Balan, C., Autor
Barrow, P., Autor
Baudis, L., Autor
Bauermeister, B., Autor
Behrens, A., Autor
Beltrame, P., Autor
Bokeloh, K., Autor
Breskin, A., Autor
Brown, A., Autor
Brown, E., Autor
Brünner, Stefan1, Autor           
Bruno, G., Autor
Budnik, R., Autor
Cardoso, J. M. R., AutorColijn, A. P., AutorContreras, H., AutorCussonneau, J. P., AutorDecowski, M. P., AutorDuchovni, E., AutorFattori, S., AutorFerella, A. D., AutorFulgione, W., AutorGarbini, M., AutorGeis, C., AutorGoetzke, L. W., AutorGrignon, C., AutorGross, E., AutorHampel, W., AutorItay, R., AutorKaether, F.1, Autor           Kessler, G., AutorKish, A., AutorLandsman, H., AutorLang, R. F., AutorCalloch, M. Le, AutorLellouch, D., AutorLevinson, L., AutorLevy, C., AutorLindemann, Sebastian1, Autor           Lindner, M.1, Autor           Lopes, J. A. M., AutorLung, K., AutorLyashenko, A., AutorMacMullin, S., AutorMarrodán Undagoitia, Teresa1, Autor           Masbou, J., AutorMassoli, F. V., AutorParas, D. Mayani, AutorFernandez, A. J. Melgarejo, AutorMeng, Y., AutorMessina, M., AutorMiguez, B., AutorMolinario, A., AutorMorana, G., AutorMurra, M., AutorNaganoma, J., AutorOberlack, U., AutorOrrigo, S. E. A., AutorPantic, E., AutorPersiani, R., AutorPiastra, F., AutorPienaar, J., AutorPlante, G., AutorPriel, N., AutorReichard, S., AutorReuter, C., AutorRizzo, A., AutorRosendahl, S., AutorSantos, J. M. F. dos, AutorSartorelli, G., AutorSchindler, S., AutorSchreiner, J.1, Autor           Schumann, M., AutorLavina, L. Scotto, AutorSelvi, M., AutorShagin, P., AutorSimgen, H.1, Autor           Teymourian, A., AutorThers, D., AutorTiseni, A., AutorTrinchero, G., AutorVitells, O., AutorWang, H., AutorWeber, M.1, Autor           Weinheimer, C., Autor mehr..
Affiliations:
1Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society, ou_904549              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Astrophysics, Instrumentation and Methods for Astrophysics, astro-ph.IM, Physics, Instrumentation and Detectors, physics.ins-det
 Zusammenfassung: XENON is a direct detection dark matter project, consisting of a time projection chamber (TPC) that uses xenon in double phase as a sensitive detection medium. XENON100, located at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, is one of the most sensitive experiments of its field. During the operation of XENON100, the design and construction of the next generation detector (of ton-scale mass) of the XENON project, XENON1T, is taking place. XENON1T is being installed at LNGS as well. It has the goal to reduce the background by two orders of magnitude compared to XENON100, aiming at a sensitivity of $2 \cdot 10^{-47} \mathrm{cm}^{\mathrm{2}}$ for a WIMP mass of 50 GeV/c$^{2}$. With this goal, an active system that is able to tag muons and their induced backgrounds is crucial. This active system will consist of a water Cherenkov detector realized with a water volume $\sim$10 m high and $\sim$10 m in diameter, equipped with photomultipliers of 8 inches diameter and a reflective foil. In this paper we present the design and optimization study for this muon veto water Cherenkov detector, which has been carried out with a series of Monte Carlo simulations, based on the GEANT4 toolkit. This study showed the possibility to reach very high detection efficiencies in tagging the passage of both the muon and the shower of secondary particles coming from the interaction of the muon in the rock: >99.5% for the former type of events (which represent $\sim$ 1/3 of all the cases) and >70% for the latter type of events (which represent $\sim$ 2/3 of all the cases). In view of the upgrade of XENON1T, that will aim to an improvement in sensitivity of one order of magnitude with a rather easy doubling of the xenon mass, the results of this study have been verified in the upgraded geometry, obtaining the same conclusions.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2014-11-06
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1088/1748-0221/9/11/P11006
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Instrumentation
  Andere : Jinst
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 9 (11) Artikelnummer: P11006 Start- / Endseite: - Identifikator: ISSN: 1748-0221
CoNE: https://pure.mpg.de/cone/journals/resource/1000000000221510