English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  The Fddd four-circle diffractometer for single-crystal X-ray studies at temperatures down to 9 K

Copley, R., Goeta, A., Lehmann, C. W., Cole, J., Yufit, D., Howard, J., et al. (1997). The Fddd four-circle diffractometer for single-crystal X-ray studies at temperatures down to 9 K. Journal of Applied Crystallography, 30, 413-417. doi:10.1107/S0021889897002525.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Copley, R.C.B.1, Author
Goeta, A.E.1, Author
Lehmann, C. W.1, 2, Author           
Cole, J.C.1, Author
Yufit, D.S.1, Author
Howard, J.A.K.1, Author
Archer, J.M.3, Author
Affiliations:
1Department of Chemistry, University of Durham, South Road, Durham DH1 3LE, England,, ou_persistent22              
2Service Department Lehmann (EMR), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445625              
3lnstitut Max von Laue Paul Langevin, F-38042 Grenoble, France. E-mail: j.a.k.howard@durham.ac.uk, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: The Fddd four-circle diffractometer system has been developed to perform X-ray diffraction experiments at temperatures as low as 9 K. The diffractometer consists of: (i) a Siemens rotating-anode generator; (ii) a Huber goniometer with offset X circle; (iii) a Siemens Fast Scintillation Detector; and (iv) an APD `202' Displex cryogenic refrigerator. The belt-driven rotating anode gives an X-ray flux that is far in excess of that obtained from a sealed X-ray tube and leads to faster data collections and the opportunity to study smaller samples. X-ray beam alignment requires precise movements of the 300 kg goniometer and this is achieved using compressed air pads. Steel-braided gas lines that allow the transfer of helium gas between the Displex and the compressor are supported by a counterbalance system. The stress on these lines has been reduced by attaching them to the Displex via high-pressure rotating joints and by passing them through a metal ring that is attached to the circle. A compact vacuum gauge has been mounted through one of the four ports on the top of the cryostat and gives valuable information on the pressure within the Displex sample chamber during an experiment. Crystals are mounted on sharpened 0.3 mm graphite pencil leads that are held in a newly designed sample mount. The temperature reported from the second stage of the Displex has been assessed by consideration of temperature standards that include the solid-state phase transitions of benzil (1,2-diphenylethanedione) and terbium vanadate.

Details

show
hide
Language(s): eng - English
 Dates: 1997
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1107/S0021889897002525
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Applied Crystallography
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Oxford, England : Blackwell Publishing on behalf of the International Union of Crystallography
Pages: - Volume / Issue: 30 Sequence Number: - Start / End Page: 413 - 417 Identifier: ISSN: 0021-8898
CoNE: https://pure.mpg.de/cone/journals/resource/954925410812