English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Wireless Amplified NMR detector (WAND) for high resolution in-vivo image of internal organs

Qian, C., Yu, X., Chen, D.-Y., Dodd, S., Bouraoud, N., Pothayee, N., et al. (2013). Wireless Amplified NMR detector (WAND) for high resolution in-vivo image of internal organs. Radiology, 268(1), 228-236. doi:10.1148/radiol.13121352.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Qian, C, Author
Yu, X1, Author           
Chen, D-Y, Author
Dodd, S, Author
Bouraoud , N, Author
Pothayee, N, Author
Chen, Y, Author
Beeman, S, Author
Bennett, K, Author
Murphy-Boesch, J, Author
Koretsky, A, Author
Affiliations:
1National Institutes of Health, Bethesda, MD, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Purpose To assess the feasibility of imaging deep-lying internal organs at high spatial resolution by imaging kidney glomeruli in a rodent model with use of a newly developed, wireless amplified nuclear magnetic resonance (MR) detector. Materials and Methods This study was approved by the Animal Care and Use Committee at the National Institutes of Health/National Institute of Neurologic Disorder and Stroke. As a preclinical demonstration of this new detection technology, five different millimeter-scale wireless amplified nuclear MR detectors configured as double frequency resonators were chronically implanted on the medial surface of the kidney in five Sprague-Dawley rats for MR imaging at 11.7 T. Among these rats, two were administered gadopentetate dimeglumine to visualize renal tubules on T1-weighted gradient-refocused echo (GRE) images, two were administered cationized ferritin to visualize glomeruli on T2*-weighted GRE images, and the remaining rat was administered both gadopentetate dimeglumine and cationized ferritin to visualize the interleaved pattern of renal tubules and glomeruli. The image intensity in each pixel was compared with the local tissue signal intensity average to identify regions of hyper- or hypointensity. Results T1-weighted images with 70-μm in-plane resolution and 200-μm section thickness were obtained within 3.2 minutes to image renal tubules, and T2*-weighted images of the same resolution were obtained within 5.8 minutes to image the glomeruli. Hyperintensity from gadopentetate dimeglumine enabled visualization of renal tubules, and hypointensity from cationic ferritin enabled visualization of the glomeruli. Conclusion High-spatial-resolution images have been obtained to observe kidney microstructures in vivo with a wireless amplified nuclear MR detector.

Details

show
hide
Language(s):
 Dates: 2013-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1148/radiol.13121352
BibTex Citekey: QianYCDBPCBBMK2013
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Radiology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 268 (1) Sequence Number: - Start / End Page: 228 - 236 Identifier: -