Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  High-resolution Fourier-encoded sub-millisecond echo time musculoskeletal imaging at 3 Tesla and 7 Tesla

Deligianni, X., Bär, P., Scheffler, K., Trattnig, S., & Bieri, O. (2013). High-resolution Fourier-encoded sub-millisecond echo time musculoskeletal imaging at 3 Tesla and 7 Tesla. Magnetic Resonance in Medicine, 70(5), 1434-1439. doi:10.1002/mrm.24578.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Deligianni, X, Autor
Bär, P, Autor
Scheffler, K1, 2, Autor           
Trattnig, S, Autor
Bieri, O, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose: The feasibility of imaging musculoskeletal fibrous tissue components, such as menisci, ligaments, and tendons, with a conventional spoiled gradient echo technique is explored in vivo at 3 T and 7 T. Methods: To this end, the echo time (TE1) of a conventional Fourier-encoded multicontrast three-dimensional SGPR sequence is minimized by using nonselective excitation pulses, highly asymmetric readouts, and a variable TE1 along the phase and slice encoding direction. In addition, a fully sampled second echo image (with TE2 >> TE1) can be used to highlight components with short transverse relaxation times in a difference image with positive contrast. Results: Fourier-encoded spoiled gradient echo sequences are able to provide sub-millisecond TE1 of about 800 μs for typical in-plane resolutions of about 0.5 x 0.5 mm2. As a result, high-resolution positive contrast images of fibrous tissues can be generated within clinically feasible scan-time of about 2–7 minutes. Conclusion: After optimization, Fourier-encoded spoiled gradient echo provides a highly robust and flexible imaging technique for high-resolution positive contrast imaging of fibrous tissue that can readily be used in the clinical routine.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2012-122013-11
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.24578
BibTex Citekey: DeligianniBSTB2012
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 70 (5) Artikelnummer: - Start- / Endseite: 1434 - 1439 Identifikator: -