日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  A new method for estimating population receptive field topography in visual cortex

Lee, S., Papanikolaou, A., Logothetis, N., Smirnakis, S., & Keliris, G. (2013). A new method for estimating population receptive field topography in visual cortex. NeuroImage, 81, 144-157. doi:10.1016/j.neuroimage.2013.05.026.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

作成者

表示:
非表示:
 作成者:
Lee, S1, 2, 著者           
Papanikolaou, A1, 2, 著者           
Logothetis, NK1, 2, 著者           
Smirnakis, SM, 著者           
Keliris, GA1, 2, 著者           
所属:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: We introduce a new method for measuring visual population receptive fields (pRF) with functional magnetic resonance imaging (fMRI). The pRF structure is modeled as a set of weights that can be estimated by solving a linear model that predicts the Blood Oxygen Level-Dependent (BOLD) signal using the stimulus protocol and the canonical hemodynamic response function. This method does not make a priori assumptions about the specific pRF shape and is therefore a useful tool for uncovering the underlying pRF structure at different spatial locations in an unbiased way. We show that our method is more accurate than a previously described method (Dumoulin and Wandell, 2008) which directly fits a 2-dimensional isotropic Gaussian pRF model to predict the fMRI time-series. We demonstrate that direct-fit models do not fully capture the actual pRF shape, and can be prone to pRF center mislocalization when the pRF is located near the border of the stimulus space. A quantitative comparison demonstrates that our method outperforms the direct-fit methods in the pRF center modeling by achieving higher explained variance of the BOLD signal. This was true for direct-fit isotropic Gaussian, anisotropic Gaussian, and difference of isotropic Gaussians model. Importantly, our model is also capable of exploring a variety of pRF properties such as surround suppression, receptive field center elongation, orientation, location and size. Additionally, the proposed method is particularly attractive for monitoring pRF properties in the visual areas of subjects with lesions of the visual pathways, where it is difficult to anticipate what shape the reorganized pRF might take. Finally, the method proposed here is more efficient in computation time than direct-fit methods, which need to search for a set of parameters in an extremely large searching space. Instead, this method uses the pRF topography to constrain the space that needs to be searched for the subsequent modeling.

資料詳細

表示:
非表示:
言語:
 日付: 2013-11
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1016/j.neuroimage.2013.05.026
BibTex参照ID: LeePLSK2013
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NeuroImage
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 81 通巻号: - 開始・終了ページ: 144 - 157 識別子(ISBN, ISSN, DOIなど): -